GTO SL-2000, SL-1000 installation manual Trouble Shooting Guide, Maintenance

Page 32

TROUBLE SHOOTING GUIDE

Maintenance:

On all gates weighing 250 lb. or more, routinely grease the ball bearing rollers at least 4 times a year; grease more frequently if the gates are near a coastal area.

Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board.

Have your gate operator tested monthly and serviced regularly by an experienced technician. The gate MUST stop and reverse on contact with an obstruction or when an object activates the non-contact sensors. If these functions are observed to operate improperly, discontinue use and have operator serviced immediately.

The operator has a 12 Vdc motor with mechanical limit switches.

To test the motor, put a voltmeter on DC and place the meter leads on the wire connections inside the plastic cover above the switches. The reading should be at least 11.5 V when the system is active. If it is not, see The Control Board section

To test the switches, put the meter on Òohms.Ó Place the leads on each of the wires on the switch. You should have an open circuit. Click the switch and you should have .2 ohms. Do this for both switches.

To test the cable, put the meter on ohms. At one end of the cable place the lead on the green wire, and on the other end of the cable place the lead on the green wire and the other wires. This should show a maximum of 1.0 ohms on the green wire and nothing on the other wires. Test each wire as you have above. If all have the proper readings, then this is not the problem.

Note: Inspect the cable for any signs of any punctures because wires inside the PVC jacket can be shorted and the cable will still show proper ohms.

The control board: This is a micro processor board. The power that runs the gate is from the battery and recharged, through the board only, by a 18 volt 40 VA. (2.9 A) transformer.

There is one (1) green and one (1) red LED (light emitting diode) on the control board. They are for a quick reference only. All readings must be measured by a voltmeter!

The red light serves two purposes. The first is to aid in storing the personal transmitter code. See ÒSetting the Personal Transmitter CodeÓ.

The second is to show the condition of the battery. If it is flashing, see the following section on Ò Testing the battery.Ó The normal state of this light is on, but dim.

If the red LED is flashing it means that the system may have reached low voltage lockout; the unit does not have enough voltage to operate the system. One of the following problems may exist:

¥Broken or spliced wires from the transformer or solar panel to the control board.

¥A transformer or solar panel that has no output voltage.

¥Incorrect number of solar panels, or solar panels not properly hooked up.

The green light serves as a quick visual indication that the control board is receiving power from the transformer.

29

Image 32
Contents Automatic Gate Operator When You Know Multiply By To Find Symbol Vehicular Gate Operator Class CategoriesTable of Contents Important Safety Instructions For the Installer Before InstallationII. During Installation For the System DesignerIII. After Installation Entrapment Alarm UL 325 Secondary Means of Protection Against EntrapmentFor the CONSUMER/END User No ONE should Cross the Path of the Moving GateRequired Safety Precautions for Gates Point hazardSeries Moving Gate Can Cause Injury Or Death GTO PRO SL-1000 Series Technical Specifications GTO PRO SL-2000 Series Technical Specifications Parts Identification Gate Preparation Single Gate Operator InstallationOverview of Operator Installation Recommended Wiring and USE of Conduit Mounting the Legs on the Slide Gate OperatorDetermining the Mounting Position and Mounting the Operator Operator side of the gate see Overview Illustration,Installing the Chain To Open the Gate ManuallyInstallation of the GTO Transformer Powering the SystemConnecting the Battery Solar Zones and Gate Activity Estimated Maximum Number of Cycles Per DayStep Another see Illustration K 18VACControl Board Settings RightPotentiometers Setting the Personal Transmitter Code Mounting the Receiver FCC RegulationAdjusting the Limit Switches If your gate opens from Right to LeftHowever, if your gate opens from Left to Right Counter ClockwiseConnecting Safety Devices Connecting Additional Safety DevicesConnecting Accessories WHT White Used with GRN GreenBLU Blue Used with GRN Green ORG Orange Used with GRN GreenAttaching the Housing Maintenance Is especially important for safety devicesTrouble Shooting Guide MaintenanceSystem Test Specifications Connected to these terminalsLimited Two Year Warranty Warranty and Repair ServiceInstructions for the Installation Dual Slide Gate System Dual Gate System Installation Second Gate Auxiliary Operator Parts & HardwareControl Unit Wiring the Second Operator This Step is for SL-2000/ 2200 Installation onlySetting the Control Board for Dual Gate Installations Refer to the illustrations on the nextStep Accessories Available Through Your Dealer GTO Digital Keypad F300ACCESS-ORIES Replacement Batteries Installation Check List Installation of this operator conforms to Class

SL-1000, SL-2000 specifications

The GTO SL-2000 and SL-1000 are advanced gate operators designed for efficient and reliable automation of heavy-duty swing gates. These models are renowned for their robust construction and innovative technologies that enhance both performance and security.

The SL-2000 is particularly suited for large, dual-swing gates weighing up to 2,000 pounds, making it a perfect choice for commercial and industrial settings. In comparison, the SL-1000 is designed for lighter gates that weigh up to 1,000 pounds, suitable for residential and light commercial applications. Both models are engineered to provide smooth, quiet operation, which is vital for residential areas where noise reduction is essential.

One of the standout features of both the SL-2000 and SL-1000 is their advanced DC motor technology. This allows for variable speed operation, providing a slower, more controlled movement during the opening and closing cycles. Such functionality not only enhances safety but also minimizes wear and tear on the gate mechanism, ensuring longevity.

Both models are equipped with obstacle detection technology that halts the gate's movement if an obstruction is encountered. This safety feature helps prevent accidents and damage, a critical aspect in environments where individuals and vehicles are present.

In terms of installation, the GTO SL series is designed for ease of use, featuring a straightforward setup process with clear instructions and minimal tools required. Additionally, the SL-2000 and SL-1000 include a built-in rechargeable battery backup, ensuring that the gate operates even during power outages.

Security is a top priority with both gate operators. They incorporate rolling code technology in their remote controls, which changes the access code with each activation, significantly reducing the risk of unauthorized access. Furthermore, the SL series supports multiple remote controls, allowing for convenient access for users while maintaining security.

Durability is another hallmark of the GTO SL-2000 and SL-1000. Both operators are built with weather-resistant materials, ensuring they can withstand various environmental conditions. This resilience makes them a solid investment for long-term use.

In conclusion, the GTO SL-2000 and SL-1000 are state-of-the-art gate operators that combine cutting-edge technology with superior safety features, making them a reliable choice for enhancing the automation of swing gates in diverse applications. Their ease of installation, robust construction, and advanced functionalities are significant advantages for property owners seeking secure and efficient access solutions.