i.Cold Coolant – Liquid nitrogen, a cryogenic liquid, is used in traps. If it is splashed on body tis- sues or eyes, it can cause severe frostbite or blindness. The extremely low temperature of lique- fied nitrogen can cause skin damage similar to high temperature burns. Contact with the cold gas evolving from the liquid may produce the same effect. Delicate tissues, such as the eye tissues, are most easily damaged by exposure to cold gas or liquid. To minimize the risk of hazardous con- tact of cold gaseous nitrogen with any part of the body, wear personal safety equipment recom- mended for use with cryogenic materials including face shield, full-sleeved lab coat, and clean, dry gloves which fit loosely so they can be thrown off quickly if frozen by contact with the gas.

j.Asphyxiation – If a large amount of liquid nitrogen is spilled in a small, poorly ventilated room or equipment, death from suffocation can result. All diffusion pumps are typically cleaned with ace- tone or alcohol. Acetone, alcohol, and most other solvents are very volatile (unstable). During cleaning, the volatility of these cleaners may permit their gases to displace air and its life-support- ing oxygen which could cause death or serious injury by asphyxiation. Always ensure that clean- ing operations are performed in large, well-ventilated areas.

j.While still hot, the diffusion pump may also contain decomposed and/or overheated pump oils which can also be an asphyxiant.

k.Large, Heavy Weights – Diffusion pumps larger than 10 inches in diameter require power-assist- ed equipment and the use of trained moving/installation personnel in order to avoid dropping, slip- ping, and/or overturning the pump thus severely injuring personnel. Check weight of equipment before lifting and do not stand under equipment being moved.

vii

Image 11
Contents HS-20 Diffusion Pump Sales and Service Offices Telephone Numbers Warranty Replacement and Adjustment WarrantyPage Page Iii Prohibited Action Explosion-Causing Condition Prohibited Action Result Page Vii Page Page Section Safety Considerations Section I Installation Table of ContentsList of Tables List of IllustrationsModel Technical Specifications Installation GeneralOperating Specifications See Figure ASA Outline Drawing HS-20 Diffusion Pump, with ASA Flanges Unpacking Cleaning a NEW PumpInstallation Cooling Water Connections See Figure Safety Considerations and InterlocksUtility and System Connections Vacuum ConnectionsCooling Water Connections Initial Vacuum Test Thermal Switches240/400/430/440/480 V Wiring Diagram HS-20 Diffusion Pump 415 V Wiring Diagram HS-20 Diffusion Pump Adding Pump Fluid Sight Glass Assembly Operation START-UP ProcedureOperation Shutdown ProcedurePeriodic Inspection Maintenance GeneralCleaning MaintenanceDo not overtighten the screw Disassembling and Reassembling the Cold CAP Refer to FigureExternal Fittings Cold Cap Assembly Disassembling the Lower Jet Assembly JET AssemblyDisassembling the Jet Assembly Refer to Figure Inch Jet Assembly Heater Replacement Maintenance Reassembling the Lower Jet AssemblyReassembling the Jet Assembly Jet Coupling Tighten clamping nuts to 250 in.-lbs Maintenance Replaceable Parts Maintenance Poor Pump or System Performance Troubleshooting LeakageOutgassing Troubleshooting