Installation

a.The recommended fluid charge for the pump is five U. S. quarts. The fluid charge will gradually be depleted through use, but the pump will continue to operate normally. When the charge is reduced to approximately 60% of the initial amount, the boiler temperature may begin to rise and under this condition the thermal switch is designed to open the heater circuit.

b.This diffusion pump is furnished with fill and drain fittings with special Viton elastomer sealed plugs.

c.If the pump is hot, wait until the pump has cooled then vent it to atmosphere. Remove the plug from the filling port of the pump and install the needed quantity of fluid up to the FULL COLD level indicator on the sight glass (see Figure 1-5). The fluid can also be poured in from the pump inlet or foreline.

d.Replace the fill plug with a new Viton gasket. Tighten the fill plug using moderate torque (75 inch-pounds maximum). Lubricate the O-ring with pump fluid before installation.

e.Once the pump is running, the oil level should be in the FULL HOT operating range as indi- cated on the sight glass assembly.

Figure 1-6. Sight Glass Assembly

NOTE

________

It is not recommended that Santovac 5 diffusion pump fluid be used with the HS-20.

1-12

Image 27
Contents HS-20 Diffusion Pump Sales and Service Offices Telephone Numbers Warranty Replacement and Adjustment WarrantyPage Page Iii Prohibited Action Explosion-Causing Condition Prohibited Action Result Page Vii Page Page Section Safety Considerations Section I Installation Table of ContentsList of Tables List of IllustrationsInstallation General Operating Specifications See FigureModel Technical Specifications ASA Outline Drawing HS-20 Diffusion Pump, with ASA Flanges Unpacking Cleaning a NEW PumpInstallation Cooling Water Connections See Figure Safety Considerations and InterlocksUtility and System Connections Vacuum ConnectionsCooling Water Connections Initial Vacuum Test Thermal Switches240/400/430/440/480 V Wiring Diagram HS-20 Diffusion Pump 415 V Wiring Diagram HS-20 Diffusion Pump Adding Pump Fluid Sight Glass Assembly Operation START-UP ProcedureOperation Shutdown ProcedurePeriodic Inspection Maintenance GeneralCleaning MaintenanceDo not overtighten the screw Disassembling and Reassembling the Cold CAP Refer to FigureExternal Fittings Cold Cap Assembly JET Assembly Disassembling the Jet Assembly Refer to FigureDisassembling the Lower Jet Assembly Inch Jet Assembly Maintenance Reassembling the Lower Jet Assembly Reassembling the Jet AssemblyHeater Replacement Jet Coupling Tighten clamping nuts to 250 in.-lbs Maintenance Replaceable Parts Maintenance Troubleshooting Leakage OutgassingPoor Pump or System Performance Troubleshooting