Installation

WARNING

_____________

Diffusion pumps are typically cleaned with acetone, alcohol, or other solvents.

When heated, sprayed or exposed to high temperature equipment, these solvents become flammable and explosive, causing serious injury or death. Do not use near high temperature source. Ventilate work- ing area with a blower and use in large, well-ventilated room. When heated or sprayed, acetone or alcohol also becomes 4 to 5 times heav- ier than air and will flow down, settling in tanks, pits, and low areas, thus displacing air which can kill by asphyxiation. Use in a large, well- ventilated room. Use of a self-contained breathing apparatus may be necessary.

Acetone, alcohol, and other solvents are irritants, narcotics, depres- sants, and/or carcinogenics. Their inhalation and/or ingestion may pro- duce serious effects. Prolonged or continued contact with the skin will result in absorption through the skin and moderate toxicity. Always ensure that cleaning operations are carried out in large, well-ventilated rooms, and wear eyeshields, gloves, and protective clothing.

e.Remove all traces of the cleaning fluid by carefully drying with clean, dry, oil-free compressed air.

f.For reassembly, reverse the above procedure.

g.Clean the flanges and O-ring grooves thoroughly with acetone or alcohol, using clean, lint free rags.

CAUTION

Alcohol, acetone, and other solvents degrade O-ring materials reducing their ability to hold a vacuum. Do not use any solvents on O-rings. If necessary to clean O-rings, wipe with lint-free, clean cloth, wash in detergent and water, or use a small amount of pump oil.

h.Remove all traces of acetone or alcohol by carefully drying with clean, dry, oil-free com- pressed air. Install O-ring gasket.

1-5

Image 20
Contents HS-20 Diffusion Pump Sales and Service Offices Telephone Numbers Warranty Warranty Replacement and AdjustmentPage Page Iii Prohibited Action Explosion-Causing Condition Prohibited Action Result Page Vii Page Page Table of Contents Section Safety Considerations Section I InstallationList of Illustrations List of TablesModel Technical Specifications Installation GeneralOperating Specifications See Figure ASA Outline Drawing HS-20 Diffusion Pump, with ASA Flanges Cleaning a NEW Pump UnpackingInstallation Safety Considerations and Interlocks Utility and System ConnectionsVacuum Connections Cooling Water Connections See FigureCooling Water Connections Thermal Switches Initial Vacuum Test240/400/430/440/480 V Wiring Diagram HS-20 Diffusion Pump 415 V Wiring Diagram HS-20 Diffusion Pump Adding Pump Fluid Sight Glass Assembly START-UP Procedure OperationShutdown Procedure OperationMaintenance General Periodic InspectionMaintenance CleaningDisassembling and Reassembling the Cold CAP Refer to Figure Do not overtighten the screwExternal Fittings Cold Cap Assembly Disassembling the Lower Jet Assembly JET AssemblyDisassembling the Jet Assembly Refer to Figure Inch Jet Assembly Heater Replacement Maintenance Reassembling the Lower Jet AssemblyReassembling the Jet Assembly Jet Coupling Tighten clamping nuts to 250 in.-lbs Maintenance Replaceable Parts Maintenance Poor Pump or System Performance Troubleshooting LeakageOutgassing Troubleshooting