ENGLISH
PROBLEM SOLVING
Note: Turn off the switch and unplug the electrical cord before servicing.
For additional information call
Problem | Cause | Solution |
Suction Motor will not start | Electric plug | • Push plug securely into outlet |
Agitator Motor will not start |
| • Try another outlet |
|
| • Check circuit breaker |
| Suction motor power switch and/or agitator | • Make sure power switch is in “ON” position |
| motor power switch are not turned “ON” |
|
|
|
|
Cleaning solution and | Low water level in clean water tank | • Check the water level in the clean water tank and refill |
water are not released |
|
|
from the carpet nozzle | Clean water or detergent tank | • Be sure clean water tank and detergent tank are both locked |
| incorrectly installed | securely in place |
| Carpet nozzle area clogged | • Remove debris from the carpet nozzle area |
|
|
|
Cleaning solution and | Low water level in clean water tank | • Check the water level in the clean water tank and refill |
water are not released |
|
|
from the Upholstery/stair | Clean water or detergent tank | • Be sure clean water tank and detergent tank are both locked |
nozzle | incorrectly installed | securely in place |
| Clog in upholstery/stair nozzle | • Clear the Upholstery/stair nozzle of debris |
| Hose adapter not fully installed | • Press down firmly on hose adapter |
| Suction nozzle not correctly installed | • Make sure nozzle is fully engaged into adapter handle (see pg. 14) |
|
|
|
Does not pick up the | Recovery tank is full | • Empty the recovery tank and return to cleaner. Resume cleaning |
dispensed cleaning solution |
|
|
and water from carpet | Recovery tank is not fully installed | • Make sure recovery tank is securely locked in position |
| Clear suction cover is not fastened at the corners | • Check to see that the suction cover release tabs are fastened properly |
| Hose attachment cover is not completely closed | • Press cover down firmly to snap closed |
|
|
|
Does not clean the carpet | Improper cleaning solution used | • Use genuine Eureka Carpet/Upholstery Cleaning solution |
| Adjustable shampoo control lever in wrong | • Move lever upward to increase amount of detergent used |
| position |
|
| Agitator brush not installed correctly | • Make sure agitator brush is fully snapped into place and is allowed |
|
| to move freely |
| Agitator brush not moving | • Make sure power switch is in right position for agitation. |
|
|
|
Minimal suction at the end | Upholstery/stair nozzle is clogged | • Remove any visible clogs from the nozzle that may restrict airflow. |
of the hose | Hose adapter not fully installed | • Press down firmly on the hose adapter |
| ||
| Suction nozzle not correctly installed | • Make sure nozzle is fully engaged into adapter handle (see pg. 14) |
|
|
|
Suction shuts off | Excessive foam in the recovery tank | • Empty recovery tank, then flush with clean water |
prematurely | Improper cleaning solution used | • Use genuine Eureka Carpet/Upholstery Cleaning solution |
| ||
|
|
|
Automatic suction shut off | Float may be binding in cage | • Remove automatic suction shut off assembly from recovery tank and |
does not shut off |
| remove any hair or debris. Check for free movement of float in cage. |
|
|
|
20