GE GXSF30H Open a Nearby Soft Water Faucet, If the code was changed, make ALL the timer settings

Page 17

ge.com

Service: Manually Initiated Electronics Diagnostics

1. To enter diagnostics, press and hold the

Turbine Switches

 

MODE button until (000 – –) shows in the

 

 

 

 

 

 

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

 

display.

 

 

 

 

 

 

A The first 3 digits indicate water meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation as follows:

Water Switch (B)

000 (steady) = soft water not in

Meter

(A)

use…no flow through the meter.

 

 

 

 

 

 

 

 

—OPEN A NEARBY SOFT WATER FAUCET—

000 to 199 (continual) = repeats display for each gallon of water passing through the meter.

Motor

Position

switch

Sensor

housing Turbine

Valve

Turbine support

and shaft

outlet

 

If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.

BThe letter (P) and dash(es) indicate POSITION switch operation. The letter appearing means the switch is closed; the dash means the switch is open. Use the

RECHARGE (RECHARGE TONIGHT–RECHARGE NOW) button to manually advance the valve into each cycle and check correct switch operation.

CORRECT SWITCH

 

DISPLAYS

VALVE CYCLE STATUS

— Valve in service, fill, brining, backwash or fast rinse position.

— P

Valve rotating from one position to

 

another

CWhile in this diagnostic screen, the following information is available and may be beneficial for various reasons. This information is retained by the computer from the first time electrical power is applied to the control.

Press and hold the UP button to display the number of days this control has had electrical power applied.

Press and hold the DOWN button to display the number of regenerations initiated by this control since the SR code number was entered.

2.Press the MODE button and hold in three

seconds until a Service Rating code appears in the display.

For correct water softening system

operation, the model code must be F30 for model GXSF30H.

To reset the code, press the UP or DOWN button until the correct number shows.

3.Press the MODE button to return to the present time display.

If the code was changed, make ALL the timer settings.

NOTE: If the control is left in a diagnostic display or a flashing display when setting times or hardness, present time automatically returns if a button is not pressed within four minutes.

17

Image 17
Contents Care and Cleaning Safety Information7283918 215C1173P021 49-5017706-06 JR Write the model and serial numbers here Model #Safety Precautions Important Installation Recommendations Before Beginning InstallationTransit Where to Install the SoftenerUnpacking and Inspection Typical Installation Illustration Plan HOW YOU will Install the SoftenerBefore YOU Begin Install Bypass ValvePlumb in and OUT Pipes to and from Softener Connect and RUN the Valve Drain HoseConnecting a Rigid Valve Drain Tube Install the Brine TankWith salt Install Grounding ClampADD Water and Salt to the Brine Tank Programming the Control Connect to Electrical PowerSET Present Time of DAY SET Water Hardness NumberSYSTEM/ELECTRONIC Diagnostics Optional Control SettingsError Signals SET Recharge Starting Time19″ 471⁄2″ 411⁄4″ 16″ Sanitizing ProceduresSPECIFICATIONS/DIMENSIONS About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi AssemblyFeature Memory Feature Optional Recharge ControlsFeature/Service Automatic Electronic Diagnostics Normal Operation, Control DisplaysService Timer/Softener, Service Checkout Procedure Service Electronic Demand Time Features and ServiceTo remove an error code 1. Unplug transformer ERROpen a Nearby Soft Water Faucet If the code was changed, make ALL the timer settingsIf the water softening system does not draw brine, check Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System What To Do Before you call for service…No soft water Taken not plumbed to soft waterWater in brine tank Excessive/high levelSalty tasting or Brown/yellow colored Water after installationBrown/yellow Colored water Resin beads showingParts list Parts list General Electric Parts Catalog Parts catalogSupport Screen Warrantor General Electric Company. Louisville, KY What Is Not CoveredFor The Period We Will Replace For The Period Of We Will Replace GE Water Softening System Warranty. For Customers in CanadaWarrantor Mabe Canada INC One YearDe averías Cómo limpiar la ensambladuraDe agua Cuidado y limpieza Advertencia No use con agua AdvertenciaRecomendaciones Importantes Para LA Instalación Instrucciones de instalaciónDonde Instalar EL Descalcificador Desempacado E InspecciónHerramientas Y Materiales Necesarios Para LA Instalación Use la válvula de bypass incluida para instalarIlustración DE Instalación Normal Planifique LA Instalación DEL DescalcificadorInstale LA Válvula DE Bypass Antes DE ComenzarConecte LAS Tuberías QUE Entran Y Salen DEL Descalcificador Retire el descalcificador del lugar de instalaciónCómo Conectar UN Tubo DE Drenaje DE Válvula Rígida Salmuera Y LA MangueraCont Instale LA Abrazadera DE Tierra Ajuste LA Hora DEL DÍA Conectar a LA Fuente EléctricaProgramación DEL Control DEL Sistema Ajustes Opcionales DE ControlEficiencia DE LA SAL Botones UP Down Para fijar laNi infectarán su suministro de agua ni causarán que Procedimientos DE DesinfecciónEn la fábrica se siguen los cuidados para mantener Sobre el sistema de descalcificación de agua Cómo romper un puente de sal Cómo limpiar la ensambladura de la boquilla y el Venturi Función Controles opcionales de recargado Operación normal, Pantalla de controlFunción Memoria Característica/Servicio Diagnóstico electrónico automáticoVisualizado Abra UN Grifo DE Agua Descalcificada QUE Esté Cerca Servicio Diagnóstico electrónico iniciado manualmenteServicio Inspección manual del avance de la recarga Precaución Cuidado y limpieza del sistema de descalcificación de aguaQué hacer Antes de llamar para solicitar servicio…Consejos para la identificación y solución de averías El agua sabe a sal o tiene Notas Ge.com Lista de partes Ge.com Catálogo DE Partes DE General Electric Catálogo de partesInterruptor Lo que no está cubierto Garantía GE para el Sistema de Descalcificación de AguaPor el período de Reemplazamos Solicite una reparación Soporte al Consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio