(7) SWING ( ) mode
By selecting SWING mode with VANE CONTROL button, the horizontal vane swings vertically.
(8) Cold air prevention in HEAT operation
The horizontal vane position is set to Upward.
NOTE : When 2 or more indoor units are operated with multi outdoor unit, even if any indoor unit turns thermostat off, this control doesn’t work in the indoor unit.
(9) To change the airflow direction not to blow directly onto your body.
To change the air | When to use this function? | COOL/DRY |
| HEAT |
flow direction |
| |||
|
|
|
| |
|
|
|
| |
Pressing and holding | Use this function if you don’t | The air conditioner starts the | The air conditioner starts heat- | |
VANE CONTROL | want the air from the indoor | cooling or drying operation | ing operation approx. 3 minutes | |
button for 2 seconds | unit to blow directly onto your | approx. 3 minutes after the | after the vane has moved to the | |
or more cause | body. | vane has moved to the hori- | horizontal position. | |
the horizontal vane | • Depending on the shape of | zontal position. | • | Sometimes the area |
to reverse and | the room, the air may blow | • When VANE CONTROL |
| around your feet may not |
move to horizontal | directly onto your body. | button is pressed again, |
| warm. To warm the area |
position. | • Press VANE CONTROL | the vane returns to the |
| around the feet, set the |
|
| horizontal vane to | ||
| button again to return the | and the air conditioner |
| (AUTO) or the downward- |
| vane to the | starts the cool or dry |
| blowing position. |
| position. | operation in approx. |
|
|
Horizontal |
| 3 minutes. | • | When VANE CONTROL |
|
|
| button is pressed again, | |
position |
|
|
| |
|
|
| the vane returns to the | |
|
|
|
| |
|
|
|
| |
|
|
|
| and the air conditioner |
|
|
|
| starts the heat operation |
|
|
|
| in approx. 3 minutes. |
|
|
|
|
|
NOTE :
•If you make the airflow not to blow directly onto your body by pressing VANE CONTROL button, the compressor stops for 3 minutes even during the operation of the air conditioner.
•The air conditioner operates with Very Low speed until the compressor turns on again.
(10)ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2 °C higher. Also the horizontal vane swings in various cycle.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher, the air conditioner can keep comfort. As a result, energy can be saved.
ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL button is pressed or changed to other operation mode.
2. Vertical vane
(1)Vane motor drive
These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of the motor are controlled by pulse signals (approx. 12 V) transmitted from microprocessor.
(2)The vertical vane angle and mode change as follows by pressing WIDE VANE button.
1 2 3 4 5
(SWING)
(3)Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected angle.
Confirming of standard position is performed in the following cases:
(a)OPERATE/STOP(ON/OFF) button is pressed (POWER ON or OFF).
(b)SWING is started.
(c)The power supply turns ON.
(4)SWING( ) MODE
By selecting SWING mode with WIDE VANE button, the vertical vane swings horizontally. The remote controller dis- plays “ .”Swing mode is cancelled when WIDE MODE button is pressed once again.
14