Mitsubishi Electronics MSZ-FD25VAS, MSZ-FD35VAS service manual Troubleshooting

Page 20

10 TROUBLESHOOTING

MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS

10-1. CAUTIONS ON TROUBLESHOOTING

1.Before troubleshooting, check the following

1)Check the power supply voltage.

2)Check the indoor/outdoor connecting wire for miswiring.

2.Take care of the following during servicing

1)Before servicing the air conditioner, be sure to turn OFF the main unit first with the remote controller, and then after confirming the horizontal vane is closed, turn OFF the breaker and / or disconnect the power plug.

2)Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the P.C. board.

3)When removing the P.C. board, hold the edge of the board with care NOT to apply stress on the components.

4)When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.

Lead wiring

Housing point

3.Troubleshooting procedure

1)First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work.

2)Before servicing, check that the connector and terminal are connected properly.

3)When the P.C. board seems to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration.

4)When troubleshooting, refer to 10-2., 10-3. and 10-4.

4.How to replace batteries

Weak batteries may cause the remote controller malfunction.

In this case, replace the batteries to operate the remote controller normally.

1Remove the front lid and insert batteries. Then reattach the front lid.

2Press RESET button with tip end of ball point pen or the like, and then use the remote controller.

Insert the negative pole of the

batteries first. Check if the polarityRESET button of the batteries is correct.

NOTE : 1. If RESET button is not pressed, the remote controller may not operate correctly.

2.This remote controller has a circuit to automatically reset the microcomputer when batteries are replaced. This function is equipped to prevent the microcomputer from malfunctioning due to the voltage drop caused by the battery replacement.

5.How to install the horizontal vane

If horizontal vane is not installed correctly, all of the operation indicator lamps will blink.

In this case, install the horizontal vane correctly by following the procedures 1 to 2.

NOTE : Before installation of the horizontal vane, turn OFF the power supply.

2

In procedure 2 lock the stoppers until they click into place.

Lock

1

20

Image 20
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes Part Names and Functions See control operationIndoor model SpecificationSpecifications and rating conditions of main electric parts Noise Criteria Curves MSZ-FD25VA MSZ-FD25VASUnit mm Outlines and DimensionsWiring Diagram Refrigerant System Diagram Unit mmService Functions Timer Short ModeP.C. Board Modification for Individual Operation J1 J2Operation Remote ControllerAuto Restart Function Microprocessor Control OPERATE/STOPAuto Change Over ··· Auto Mode Operation Cool OperationDRY Operation Heat OperationHorizontal vane Auto Vane OperationOutdoor Unit MXZ series Vertical vane COOL/DRY HeatSee Sensor Area SettingSee Control Operation Daytime Plasma Operation Operation and operating rangeProgram Timer Clean OperationTimer Operation EMERGENCY/TEST Operation Minute Time Delay OperationEmergency Operation switch E.O.SW Troubleshooting Failure Mode Recall Function OFFFlow chart of Plasma operation failure mode recall function Plasma operation checkIndoor unit failure mode table Plasma operation failure mode tableInstruction of Troubleshooting StartTroubleshooting Check Table An abnormality other than above mentioned is detectedPlasma Trouble Criterion of Main Parts Troubleshooting Flow Power lamp flashes 3-time Indoor fan does not operateYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios SW P.C. Board Test Point Diagram and VoltageIndoor electronic control P.C. board CN1 Disassembly Instructions Removing the panel PhotoPower monitor receiver Removing the vertical vane motor unit Photo Removing the nozzle assembly PhotoRemoving the electrical box Photo Removing the horizontal vane motor Photo Removing the indoor fan motor and the line flow fan PhotoSpecifications subject to change without notice