Indoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remote controller.

B Check of remote controller and indoor electronic control P.C. board

wCheck if the remote controller is exclusive for this air conditioner.

Press OPERATE/STOP(ON/OFF) button on the remote controller.

Is LCD display on the remote con-

No

 

troller visible?

 

(not clear)

Yes

Replace the batteries. (Refer to 10-1.4.)

Remove the batteries, then set them back and press RESET button. (Refer to 10- 1.4.) Check if the unit operates with the remote controller.

Does the unit operate with the

No

 

remote controller?

 

Yes

 

Turn ON a radio to AM and press OPERATE/STOP(ON/OFF) button on the remote controller.

OK

Is noise heard from radio?

 

 

No

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are there any fluorescent lights of

 

 

Yes

inverter or rapid-start type within

 

 

 

 

 

 

 

 

the range of 1 m?

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the indoor electronic

 

 

 

 

control P.C. board.

 

 

 

 

(including the receiver)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller.

Reinstall the unit away from lights.

Attach a filter on receiving part.

29

Image 29
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes See control operation Part Names and FunctionsIndoor model SpecificationSpecifications and rating conditions of main electric parts MSZ-FD25VA MSZ-FD25VAS Noise Criteria CurvesUnit mm Outlines and DimensionsWiring Diagram Unit mm Refrigerant System DiagramTimer Short Mode Service FunctionsP.C. Board Modification for Individual Operation J1 J2Operation Remote ControllerAuto Restart Function OPERATE/STOP Microprocessor ControlCool Operation Auto Change Over ··· Auto Mode OperationDRY Operation Heat OperationHorizontal vane Auto Vane OperationOutdoor Unit MXZ series COOL/DRY Heat Vertical vaneSee Sensor Area SettingSee Control Operation Daytime Operation and operating range Plasma OperationProgram Timer Clean OperationTimer Operation EMERGENCY/TEST Operation Minute Time Delay OperationEmergency Operation switch E.O.SW Troubleshooting OFF Failure Mode Recall FunctionPlasma operation check Flow chart of Plasma operation failure mode recall functionPlasma operation failure mode table Indoor unit failure mode tableStart Instruction of TroubleshootingAn abnormality other than above mentioned is detected Troubleshooting Check TablePlasma Trouble Criterion of Main Parts Power lamp flashes 3-time Indoor fan does not operate Troubleshooting FlowYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios SW P.C. Board Test Point Diagram and VoltageIndoor electronic control P.C. board CN1 Removing the panel Photo Disassembly InstructionsPower monitor receiver Removing the vertical vane motor unit Photo Removing the nozzle assembly PhotoRemoving the electrical box Photo Removing the indoor fan motor and the line flow fan Photo Removing the horizontal vane motor PhotoSpecifications subject to change without notice