10-7. TEST POINT DIAGRAM AND VOLTAGE

MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS

1. Indoor electronic control P.C. board.

 

5 VDC

12 VDC

Cement resistor

 

 

 

(R111)

 

 

 

Indoor fan motor

 

 

 

(CN211)

 

 

 

1325 VDC

 

 

 

3(-) Fiducial terminal of

 

 

 

cathode side on measur-

 

 

 

ing high-voltage DC

 

 

 

415 VDC

 

 

 

5(+)3-6 VDC

 

 

 

6(+)0 or 15 VDC

Power supply input

 

 

Interlock switch(Fan)

230 VAC {

 

 

(CN1R1)

 

 

Room temperature

SW P.C. Board

 

 

thermistor RT11

Emergency

 

 

(CN111)

operation

 

 

Varistor (NR11)

switch(SW1)

 

 

CN2011

 

 

 

 

 

 

(Used for check of con-

 

 

 

ducting of thermal fuse)

 

 

 

Indoor coil thermistor

 

 

 

RT12, RT13 (CN112)

 

 

 

Plasma electrode unit

 

 

 

(CN1T1)

 

 

 

Horizontal vane(CN1U1)

 

 

 

Vertical vanes(CN151)

 

 

 

Timer short mode

 

 

 

point JPG, JPS

(LD101)

i-see Sensor

Fuse

}(Refer to 8-1.)

 

(CN110)

(F11)

 

1-3 : Connect to the monitor P.C.board

 

 

 

 

4-0 : Connect to the power monitor receiver Release of Auto restart

 

 

P.C.board

function

 

 

 

 

 

 

Solder the Jumper wire

Room temperature thermistor (RT11)

 

to JR07

 

(Refer to 8-3.)

Indoor coil thermistor (RT12, RT13)

Resistance (k")

Temperature (:)

34

Image 34
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes Part Names and Functions See control operationSpecifications and rating conditions of main electric parts SpecificationIndoor model Noise Criteria Curves MSZ-FD25VA MSZ-FD25VASWiring Diagram Outlines and DimensionsUnit mm Refrigerant System Diagram Unit mmP.C. Board Modification for Individual Operation Service FunctionsTimer Short Mode J1 J2Auto Restart Function Remote ControllerOperation Microprocessor Control OPERATE/STOPDRY Operation Auto Change Over ··· Auto Mode OperationCool Operation Heat OperationOutdoor Unit MXZ series Auto Vane OperationHorizontal vane Vertical vane COOL/DRY HeatSee Control Operation Area SettingSee Sensor Daytime Plasma Operation Operation and operating rangeTimer Operation Clean OperationProgram Timer Emergency Operation switch E.O.SW Minute Time Delay OperationEMERGENCY/TEST Operation Troubleshooting Failure Mode Recall Function OFFFlow chart of Plasma operation failure mode recall function Plasma operation checkIndoor unit failure mode table Plasma operation failure mode tableInstruction of Troubleshooting StartTroubleshooting Check Table An abnormality other than above mentioned is detectedPlasma Trouble Criterion of Main Parts Troubleshooting Flow Power lamp flashes 3-time Indoor fan does not operateYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios Indoor electronic control P.C. board Test Point Diagram and VoltageSW P.C. Board CN1 Disassembly Instructions Removing the panel PhotoPower monitor receiver Removing the electrical box Photo Removing the nozzle assembly PhotoRemoving the vertical vane motor unit Photo Removing the horizontal vane motor Photo Removing the indoor fan motor and the line flow fan PhotoSpecifications subject to change without notice