Mitsubishi Electronics MSZ-FD25VAS, MSZ-FD35VA Part Names and Functions, See control operation

Page 4

2

PART NAMES AND FUNCTIONS

MSZ-FD25VA

MSZ-FD25VAS

MSZ-FD35VA

MSZ-FD35VAS

AREA lamp

POWER lamp CLEAN lamp

PLASMA lamp

Operation Indicator

Remote control

lamp

receiving section

Front panel

 

Air filter

Air inlet

Remote controller

Plasma anti-allergy enzyme filter

Plasma electrode unit

Plasma deodorizing filter

i-see sensor

Air outlet

Fan guard

Fan

Heat exchanger

Emergency operation

Horizontal vane

 

switch

 

 

 

Vertical vane

 

AREA lamp indicate AREA setting In AREA setting, the horizontal air flow direction changes automatically according

to the detection of i-see Sensor which detects the floor/ wall temperature to air-condition the room evenly.

i-see control operation

i-see sensor constantly measure floor/wall temperature to automatically adjust to the set temperature by estimating the temperature

actually perceived by a person inside the room ("sensible temperature").

ACCESSORIES

1

Installation plate

1

 

 

 

2

Installation plate fixing screw 4 o 25 mm

5

 

 

 

3

Remote controller holder

1

 

 

 

4

Fixing screw for 3 3.5 o 1.6 mm (Black)

2

 

 

 

5

Battery (AAA) for remote controller

2

 

 

 

6

Wireless remote controller

1

 

 

 

7

Felt tape (Used for left or left-rear piping)

1

4

Image 4
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes Part Names and Functions See control operationSpecifications and rating conditions of main electric parts SpecificationIndoor model Noise Criteria Curves MSZ-FD25VA MSZ-FD25VASWiring Diagram Outlines and DimensionsUnit mm Refrigerant System Diagram Unit mmService Functions Timer Short ModeP.C. Board Modification for Individual Operation J1 J2Auto Restart Function Remote ControllerOperation Microprocessor Control OPERATE/STOPAuto Change Over ··· Auto Mode Operation Cool OperationDRY Operation Heat OperationOutdoor Unit MXZ series Auto Vane OperationHorizontal vane Vertical vane COOL/DRY HeatSee Control Operation Area SettingSee Sensor Daytime Plasma Operation Operation and operating rangeTimer Operation Clean OperationProgram Timer Emergency Operation switch E.O.SW Minute Time Delay OperationEMERGENCY/TEST Operation Troubleshooting Failure Mode Recall Function OFFFlow chart of Plasma operation failure mode recall function Plasma operation checkIndoor unit failure mode table Plasma operation failure mode tableInstruction of Troubleshooting StartTroubleshooting Check Table An abnormality other than above mentioned is detectedPlasma Trouble Criterion of Main Parts Troubleshooting Flow Power lamp flashes 3-time Indoor fan does not operateYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios Indoor electronic control P.C. board Test Point Diagram and VoltageSW P.C. Board CN1 Disassembly Instructions Removing the panel PhotoPower monitor receiver Removing the electrical box Photo Removing the nozzle assembly PhotoRemoving the vertical vane motor unit Photo Removing the horizontal vane motor Photo Removing the indoor fan motor and the line flow fan PhotoSpecifications subject to change without notice