Mitsubishi Electronics MSZ-FD25VAS Electromagnetic noise enters into TV sets or radios

Page 33

GElectromagnetic noise enters into TV sets or radios

No

Is the unit earthed?

Yes

Earth the unit.

Is the distance between the antennas and the indoor unit within 3 m, or is the distance between the antennas and the outdoor unit within 3 m?

No

Is the distance between the TV sets or radios and the indoor unit within 1 m, or is the distance between the TV sets or radios and the outdoor unit within 3 m?

No

Are the antennas damaged? Is the coaxial cable damaged? Is there any poor contact in the antenna wiring?

No

Is the indoor/outdoor connecting wire of the air conditioner and the wiring of the antennas close?

No

Yes

Yes

Yes

Yes

Extend the distance between the antennas and the indoor unit, and/or the antennas and the outdoor unit.

Extend the distance between the TV sets and/or radios and the indoor unit, or the TV sets or radios and the outdoor unit.

Replace or repair the antenna. Replace or repair the coaxial cable.

Extend the distance between the indoor/outdoor connecting wire of the air conditioner and the wiring of the antennas.

Even if all of the above conditions are fulfilled, the electromagnetic noise may enter, depending on the electric field strength or the installation condition (combination of specific conditions such as antennas or wiring).

Check the followings before asking for service. 1.Devices affected by the electromagnetic noise

TV sets, radios (FM/AM broadcast, shortwave)

2.Channel, frequency, broadcast station affected by the electromagnetic noise 3.Channel, frequency, broadcast station unaffected by the electromagnetic noise 4.Layout of ;

indoor/outdoor unit of the air conditioner, indoor/outdoor wiring, earth wire, antennas, wiring from antennas, receiver

5.Electric field intensity of the broadcast station affected by the electromagnetic noise 6.Presence or absence of amplifier such as booster

7.Operation condition of air conditioner when the electromagnetic noise enters in.

1)Turn OFF the power supply once, and then turn ON the power supply. In this situation, check for the electromagnetic noise.

2)Within 3 minutes after turning ON the power supply, press OPERATE/STOP (ON/OFF) button on the remote controller for power ON, and check for the electromagnetic noise.

3)After a short time (3 minutes later after turning ON), the outdoor unit starts running. During operation, check for the electromagnetic noise.

4)Press OPERATE/STOP (ON/OFF) button on the remote controller for power OFF, when the outdoor unit stops but the indoor/outdoor communication still runs on. In this situation, check for the electromagnetic noise.

33

Image 33
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes See control operation Part Names and FunctionsSpecification Specifications and rating conditions of main electric partsIndoor model MSZ-FD25VA MSZ-FD25VAS Noise Criteria CurvesOutlines and Dimensions Wiring DiagramUnit mm Unit mm Refrigerant System DiagramTimer Short Mode Service FunctionsP.C. Board Modification for Individual Operation J1 J2Remote Controller Auto Restart FunctionOperation OPERATE/STOP Microprocessor ControlCool Operation Auto Change Over ··· Auto Mode OperationDRY Operation Heat OperationAuto Vane Operation Outdoor Unit MXZ seriesHorizontal vane COOL/DRY Heat Vertical vaneArea Setting See Control OperationSee Sensor Daytime Operation and operating range Plasma OperationClean Operation Timer OperationProgram Timer Minute Time Delay Operation Emergency Operation switch E.O.SWEMERGENCY/TEST Operation Troubleshooting OFF Failure Mode Recall FunctionPlasma operation check Flow chart of Plasma operation failure mode recall functionPlasma operation failure mode table Indoor unit failure mode tableStart Instruction of TroubleshootingAn abnormality other than above mentioned is detected Troubleshooting Check TablePlasma Trouble Criterion of Main Parts Power lamp flashes 3-time Indoor fan does not operate Troubleshooting FlowYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios Test Point Diagram and Voltage Indoor electronic control P.C. boardSW P.C. Board CN1 Removing the panel Photo Disassembly InstructionsPower monitor receiver Removing the nozzle assembly Photo Removing the electrical box PhotoRemoving the vertical vane motor unit Photo Removing the indoor fan motor and the line flow fan Photo Removing the horizontal vane motor PhotoSpecifications subject to change without notice