Mitsubishi Electronics MSZ-FD35VA, MSZ-FD25VA Outlines and Dimensions, Wiring Diagram, Unit mm

Page 7

5

OUTLINES AND DIMENSIONS

MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS

69

43

11 X 26 Oblong hole

 

Installation plate

64

225

225

 

 

 

798

 

 

 

 

 

785

6.5

 

 

 

 

 

254

212.5

 

 

 

 

47

 

 

 

 

 

 

41

 

155

155

 

Indoor unit

54

345

330

Air in

 

 

Installation plate

257

5

 

Piping

295

56

7

 

55

688

55

100

43

Drain hose

 

 

 

 

 

85

 

58

19

 

 

97

 

 

 

 

 

Air out

Unit : mm

11 X 20 Oblong hole

64

21.5

 

 

 

211.5

231.5

253

3

 

42

69

 

 

Wall hole [65

159 Piping

Insulation

Liquid line

Gas line

Drain hose

[35 O.D

[6.35 - 0.5 m (Flared connection [6.35)

[9.52 - 0.43 m (Flared connection [9.52)

Insulation [28 O.D Connected part [16 O.D

6

WIRING DIAGRAM

MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS

7

Image 7
Contents MSZ-FD25VA E1 MSZ-FD25VAS E1 MSZ-FD35VA E1 MSZ-FD35VAS E1 Page Technical Changes See control operation Part Names and FunctionsSpecifications and rating conditions of main electric parts SpecificationIndoor model MSZ-FD25VA MSZ-FD25VAS Noise Criteria CurvesWiring Diagram Outlines and DimensionsUnit mm Unit mm Refrigerant System DiagramJ1 J2 Service FunctionsTimer Short Mode P.C. Board Modification for Individual OperationAuto Restart Function Remote ControllerOperation OPERATE/STOP Microprocessor ControlHeat Operation Auto Change Over ··· Auto Mode OperationCool Operation DRY OperationOutdoor Unit MXZ series Auto Vane OperationHorizontal vane COOL/DRY Heat Vertical vaneSee Control Operation Area SettingSee Sensor Daytime Operation and operating range Plasma OperationTimer Operation Clean OperationProgram Timer Emergency Operation switch E.O.SW Minute Time Delay OperationEMERGENCY/TEST Operation Troubleshooting OFF Failure Mode Recall FunctionPlasma operation check Flow chart of Plasma operation failure mode recall functionPlasma operation failure mode table Indoor unit failure mode tableStart Instruction of TroubleshootingAn abnormality other than above mentioned is detected Troubleshooting Check TablePlasma Trouble Criterion of Main Parts Power lamp flashes 3-time Indoor fan does not operate Troubleshooting FlowYes Check of indoor P.C. board and indoor fan motor How to check miswiring and serial signal error Check of installation of the horizontal vane Electromagnetic noise enters into TV sets or radios Indoor electronic control P.C. board Test Point Diagram and VoltageSW P.C. Board CN1 Removing the panel Photo Disassembly InstructionsPower monitor receiver Removing the electrical box Photo Removing the nozzle assembly PhotoRemoving the vertical vane motor unit Photo Removing the indoor fan motor and the line flow fan Photo Removing the horizontal vane motor PhotoSpecifications subject to change without notice