KitchenAid UXI0600DYS, UXI01200DYS installation instructions Important Safety Instructions

Page 4

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling; do not damage electrical wiring and other utilities.

Ducted fans must always be vented outdoors.

CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces, or garages.

WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a

SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

NEVER PICK UP A FLAMING PAN - you may be burned.

DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

Use an extinguisher ONLY if:

You know you have a class ABC extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it started.

The fire department is being called.

You can fight the fire with your back to an exit.

aBased on "Kitchen Fire Safety Tips" published by NFPA.

WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device.

READ AND SAVE THESE INSTRUCTIONS

4

Image 4
Contents Table of Contents/Table des matières Retractable POP-UP Downdraft Vent SystemTable of Contents Table DES MatièresVent System Safety Your safety and the safety of others are very importantImportant Safety Instructions Tools and Parts Installation RequirementsLocation Requirements Product Dimensions Models with interior-mounted blower motorCabinet Dimensions Countertop Cutout DimensionsElectrical Requirements Venting RequirementsInstallation Instructions INTERIOR-MOUNTED Vent Motor Venting MethodsIsland Location Built-In Cabinet LocationsCalculating Vent System Length Example Vent SystemInstall Vent System Determine Which Vent Direction Is Best for Your InstallationRear Mounting-Blower Motor Bottom VentingLeft or Right Venting Front ViewComplete Installation Remove the screws from the wire mounting plate¹⁄₄ x 10 8.3 x 25.4 cm Back Draft Damper Cm Round Vent Transition with DamperRemove 4 screws attaching the terminal box cover Tighten the lower support legs screwsMake Electrical Connections Check OperationInstallation Instructions EXTERIOR-MOUNTED Vent Motor Maximum Length of Vent SystemFront or Rear Venting Install Downdraft Vent In-Line External Type Blower Motor Complete Installation Exterior-Mounted MotorPrepare for Mounting the In-Line Blower System Install In-line Blower System Outlet Side Drill 4 mounting pilot holes using a ³⁄₁₆ 4.8 mm drill bitPrepare the In-line Blower System Inlet SideMake Electrical Connections for In-Line Blower Motor System Electrical Connection Inside In-line Blower SystemMake Electrical Power Supply Connection to Downdraft Vent Disconnect power Locate the downdraft vent terminal boxCheck Operation When Cooking Is Complete Vent System USEOperating Downdraft Vent To UseSurface of Downdraft Vent Vent System CareFilters Wiring Diagrams Interior-Mounted Blower MotorSEL0016521 Exterior-Mounted Blower MotorAssistance or Service AccessoriesU.S.A CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DU Système DE Ventilation Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences demplacement Exigences DinstallationOutils et pièces Dimensions du produit Modèles à ventilateur monté à lintérieurDimensions du placard RemarquesPlan de travail Dimensions des ouvertures à découper Tableau des dimensions de l’ouverture du plan de travailLongueur recommandée pour le système d’extraction Installations dans les régions au climat froidSpécifications électriques Exigences concernant l’évacuationInstructions D’INSTALLATION Ventilateur Monté À L’INTÉRIEUR Configuration en îlotMéthodes d’évacuation Calcul de la longueur effective du circuit d’évacuationInstallation du conduit d’évacuation Exemple de circuit d’évacuationRectangulaire de 3¹⁄₄ x Composant Cm x 25,4 cmÉvacuation par le bas Montage du ventilateur à l’arrière Sortie par le côté gauche ou le côté droitVue de face Vue arrièreAchever l’installation Clapet anti-retour de 3¹⁄₄ x 10 8,3 x 25,4 cmRaccord de transition rond de 6 15,2 cm avec clapet Retirer les vis de la platine de montage du câbleRaccordements électriques Ôter les 4 vis du couvercle du boîtier de connexionSerrer les vis des pieds de soutien Déconnecter la source de courant électriqueAvertissement Contrôle du fonctionnementInstructions D’INSTALLATION Ventilateur Monté À L’EXTÉRIEUR Configuration avec encastrementConfiguration en îlot- Évacuation par l’avant Configuration en îlot- Évacuation par l’arrièreÉvacuation par l’avant ou par l’arrière Achever l’installation Ventilateur monté à l’extérieur Préparation du montage du système de ventilation en ligneInstallation du système de ventilation en ligne Préparation du système de ventilation en ligneCôté sortie Côté entréeInstaller les connecteurs de conduit et le conduit dans les De conduit de ¹⁄₂ 1,3 cm homologués UL ou CSAConduit de câblage de ¹⁄₂ 1,3 cm entre le logement du Suffisamment de conduit de câblage de ¹⁄₂ 1,3 cm pourConduit de câblage ¹⁄₂ 1,3 cm Homologation UL Par le bas Utilisation DU Système D’EXTRACTION Utilisation du système d’extraction par le basUtilisation Lorsque la cuisson est terminéeEntretien DU Système D’ÉVACUATION Surface du système d’extraction par le basSchéma DE Câblage Ventilateur monté à lintérieurSEL0016521 Ventilateur monté à lextérieurAssistance OU Service AccessoiresAux États-Unis Au CanadaLa présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidComposer le 1-800-422-1230. Au Canada, composer le W10342489E