KitchenAid UXI0600DYS, UXI01200DYS installation instructions Table of Contents, Table DES Matières

Page 2

TABLE OF CONTENTS

VENT SYSTEM SAFETY

3

INSTALLATION REQUIREMENTS

5

Tools and Parts

5

Location Requirements

5

Electrical Requirements

8

Venting Requirements

8

INSTALLATION INSTRUCTIONS

 

INTERIOR-MOUNTED VENT MOTOR

9

Venting Methods

9

Install Vent System

11

Rear Mounting—Blower Motor

12

Complete Installation (Interior-Mounted Motor)

13

Make Electrical Connections

15

Check Operation

15

INSTALLATION INSTRUCTIONS

 

EXTERIOR-MOUNTED VENT MOTOR

16

Venting Methods

16

Install Vent System

17

Complete Installation (Exterior-Mounted Motor)

18

Install Downdraft Vent In-Line

 

(External Type) Blower Motor

18

Make Electrical Connections

 

for In-Line Blower Motor System

20

Make Electrical Power Supply Connection

 

to Downdraft Vent

21

Check Operation

22

VENT SYSTEM USE

23

Operating Downdraft Vent

23

VENT SYSTEM CARE

24

Surface of Downdraft Vent

24

Filters

24

WIRING DIAGRAMS

25

Interior-Mounted Blower Motor

25

Exterior-Mounted Blower Motor

26

ASSISTANCE OR SERVICE

27

In the U.S.A

27

In Canada

27

Accessories

27

WARRANTY

28

TABLE DES MATIÈRES

SÉCURITÉ DU SYSTÈME DE VENTILATION

29

EXIGENCES D'INSTALLATION

31

Outils et pièces

31

Exigences d'emplacement

31

Spécifications électriques

35

Exigences concernant l’évacuation

35

INSTRUCTIONS D’INSTALLATION

 

VENTILATEUR MONTÉ À L’INTÉRIEUR

36

Méthodes d’évacuation

36

Installation du conduit d’évacuation

37

Montage du ventilateur à l’arrière

39

Achever l’installation

40

Raccordements électriques

41

Contrôle du fonctionnement

42

INSTRUCTIONS D’INSTALLATION

 

VENTILATEUR MONTÉ À L’EXTÉRIEUR

43

Méthodes d’évacuation

43

Installation du conduit d’évacuation

44

Achever l’installation (Ventilateur monté à l’extérieur)

45

Installation du ventilateur en ligne

 

(type externe) du système d’extraction par le bas

45

Raccordements électriques

 

du système de ventilation en ligne

47

Raccordement de l’alimentation électrique

 

au système d’extraction par le bas

48

Contrôle du fonctionnement

49

UTILISATION DU SYSTÈME D’EXTRACTION

50

Utilisation du système d’extraction par le bas

50

ENTRETIEN DU SYSTÈME D’ÉVACUATION

51

Surface du système d’extraction par le bas

51

Filtres

51

SCHÉMA DE CÂBLAGE

52

Ventilateur monté à l'intérieur

52

Ventilateur monté à l'extérieur

53

ASSISTANCE OU SERVICE

54

Aux États-Unis

54

Au Canada

54

Accessoires

54

GARANTIE

55

2

Image 2
Contents Table of Contents/Table des matières Retractable POP-UP Downdraft Vent SystemTable of Contents Table DES MatièresVent System Safety Your safety and the safety of others are very importantImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Product Dimensions Models with interior-mounted blower motorCabinet Dimensions Countertop Cutout DimensionsElectrical Requirements Venting RequirementsIsland Location Installation Instructions INTERIOR-MOUNTED Vent MotorVenting Methods Built-In Cabinet LocationsCalculating Vent System Length Example Vent SystemInstall Vent System Determine Which Vent Direction Is Best for Your InstallationLeft or Right Venting Rear Mounting-Blower MotorBottom Venting Front View¹⁄₄ x 10 8.3 x 25.4 cm Back Draft Damper Complete InstallationRemove the screws from the wire mounting plate Cm Round Vent Transition with DamperRemove 4 screws attaching the terminal box cover Tighten the lower support legs screwsMake Electrical Connections Check OperationInstallation Instructions EXTERIOR-MOUNTED Vent Motor Maximum Length of Vent SystemFront or Rear Venting Prepare for Mounting the In-Line Blower System Complete Installation Exterior-Mounted MotorInstall Downdraft Vent In-Line External Type Blower Motor Prepare the In-line Blower System Install In-line Blower System Outlet SideDrill 4 mounting pilot holes using a ³⁄₁₆ 4.8 mm drill bit Inlet SideMake Electrical Connections for In-Line Blower Motor System Electrical Connection Inside In-line Blower SystemMake Electrical Power Supply Connection to Downdraft Vent Disconnect power Locate the downdraft vent terminal boxCheck Operation Operating Downdraft Vent When Cooking Is CompleteVent System USE To UseFilters Vent System CareSurface of Downdraft Vent Wiring Diagrams Interior-Mounted Blower MotorSEL0016521 Exterior-Mounted Blower MotorU.S.A Assistance or ServiceAccessories CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DU Système DE Ventilation Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences demplacement Dimensions du produit Modèles à ventilateur monté à lintérieurDimensions du placard RemarquesPlan de travail Dimensions des ouvertures à découper Tableau des dimensions de l’ouverture du plan de travailSpécifications électriques Longueur recommandée pour le système d’extractionInstallations dans les régions au climat froid Exigences concernant l’évacuationMéthodes d’évacuation Instructions D’INSTALLATION Ventilateur Monté À L’INTÉRIEURConfiguration en îlot Calcul de la longueur effective du circuit d’évacuationRectangulaire de 3¹⁄₄ x Installation du conduit d’évacuationExemple de circuit d’évacuation Composant Cm x 25,4 cmÉvacuation par le bas Vue de face Montage du ventilateur à l’arrièreSortie par le côté gauche ou le côté droit Vue arrièreRaccord de transition rond de 6 15,2 cm avec clapet Achever l’installationClapet anti-retour de 3¹⁄₄ x 10 8,3 x 25,4 cm Retirer les vis de la platine de montage du câbleSerrer les vis des pieds de soutien Raccordements électriquesÔter les 4 vis du couvercle du boîtier de connexion Déconnecter la source de courant électriqueAvertissement Contrôle du fonctionnementConfiguration en îlot- Évacuation par l’avant Instructions D’INSTALLATION Ventilateur Monté À L’EXTÉRIEURConfiguration avec encastrement Configuration en îlot- Évacuation par l’arrièreÉvacuation par l’avant ou par l’arrière Achever l’installation Ventilateur monté à l’extérieur Préparation du montage du système de ventilation en ligneCôté sortie Installation du système de ventilation en lignePréparation du système de ventilation en ligne Côté entréeConduit de câblage de ¹⁄₂ 1,3 cm entre le logement du Installer les connecteurs de conduit et le conduit dans lesDe conduit de ¹⁄₂ 1,3 cm homologués UL ou CSA Suffisamment de conduit de câblage de ¹⁄₂ 1,3 cm pourConduit de câblage ¹⁄₂ 1,3 cm Homologation UL Par le bas Utilisation Utilisation DU Système D’EXTRACTIONUtilisation du système d’extraction par le bas Lorsque la cuisson est terminéeEntretien DU Système D’ÉVACUATION Surface du système d’extraction par le basSchéma DE Câblage Ventilateur monté à lintérieurSEL0016521 Ventilateur monté à lextérieurAux États-Unis Assistance OU ServiceAccessoires Au CanadaComposer le 1-800-422-1230. Au Canada, composer le Garantie DU Système DE Ventilation KitchenaidLa présente garantie limitée ne couvre pas W10342489E