Install Vent System

WARNING

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

1.Place cardboard or similar material on top of a flat surface where you can easily assemble the downdraft vent system.

2.Remove parts packages, downdraft vent and blower box from the carton.

3.Remove all shipping materials, tape and film from the downdraft vent and blower box.

4.Install the right and left undercounter mounting brackets to the vent box. Slide the keyhole slots over the guide tabs and push the brackets up to set them in place.

B

A

C

D

A. Vent box

B. Undercounter mounting bracket

C. Keyhole slots

D. Guide tabs

5.Attach the right and left end caps to the vent box. Place the tab into the mounting slot at each end of the downdraft vent as shown and push down to lock into place.

A

B

A. End cap tab

B. Mounting slot

6.Measure distance “X” from the cabinet floor to the top of the countertop. Subtract 28¹⁄₂" from distance “X” to determine dimension “Y” (X - 28¹⁄₂ = Y).

Top of countertop

Downdraft vent

28¹⁄₂"

(73 cm)

“X”

“Y”

Cabinet floor

7.Attach the support legs to the side of the vent box with

4 - 4 x 8 mm screws in each support leg. Adjust to dimension “Y” from the bottom of the vent box to the bottom of the support legs. Tighten screws.

C

A

Dim. “Y”

B

A. Motor box

B. Support leg

C. 4 x 8 mm screws (4)

Determine Which Vent Direction Is Best for Your Installation

When installed in a cabinet, vent system can exhaust through the bottom, right or left of the cabinet.

NOTE: When using the 6" (15.2 cm) vent transition (supplied) for 6" round venting, only left or right venting is recommended.

11

Image 11
Contents Retractable POP-UP Downdraft Vent System Table of Contents/Table des matièresTable DES Matières Table of ContentsYour safety and the safety of others are very important Vent System SafetyImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Models with interior-mounted blower motor Product DimensionsCountertop Cutout Dimensions Cabinet Dimensions Venting Requirements Electrical RequirementsBuilt-In Cabinet Locations Installation Instructions INTERIOR-MOUNTED Vent MotorVenting Methods Island LocationExample Vent System Calculating Vent System LengthDetermine Which Vent Direction Is Best for Your Installation Install Vent SystemFront View Rear Mounting-Blower MotorBottom Venting Left or Right VentingCm Round Vent Transition with Damper Complete InstallationRemove the screws from the wire mounting plate ¹⁄₄ x 10 8.3 x 25.4 cm Back Draft DamperTighten the lower support legs screws Remove 4 screws attaching the terminal box coverCheck Operation Make Electrical ConnectionsMaximum Length of Vent System Installation Instructions EXTERIOR-MOUNTED Vent MotorFront or Rear Venting Prepare for Mounting the In-Line Blower System Complete Installation Exterior-Mounted MotorInstall Downdraft Vent In-Line External Type Blower Motor Inlet Side Install In-line Blower System Outlet SideDrill 4 mounting pilot holes using a ³⁄₁₆ 4.8 mm drill bit Prepare the In-line Blower SystemElectrical Connection Inside In-line Blower System Make Electrical Connections for In-Line Blower Motor SystemDisconnect power Locate the downdraft vent terminal box Make Electrical Power Supply Connection to Downdraft VentCheck Operation To Use When Cooking Is CompleteVent System USE Operating Downdraft VentFilters Vent System CareSurface of Downdraft Vent Interior-Mounted Blower Motor Wiring DiagramsExterior-Mounted Blower Motor SEL0016521Canada Assistance or ServiceAccessories U.S.AThis limited warranty does not cover Kitchenaid Ventilation WarrantyVotre sécurité et celle des autres est très importante Sécurité DU Système DE VentilationImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences demplacement Modèles à ventilateur monté à lintérieur Dimensions du produitRemarques Dimensions du placardTableau des dimensions de l’ouverture du plan de travail Plan de travail Dimensions des ouvertures à découperExigences concernant l’évacuation Longueur recommandée pour le système d’extractionInstallations dans les régions au climat froid Spécifications électriquesCalcul de la longueur effective du circuit d’évacuation Instructions D’INSTALLATION Ventilateur Monté À L’INTÉRIEURConfiguration en îlot Méthodes d’évacuationComposant Cm x 25,4 cm Installation du conduit d’évacuationExemple de circuit d’évacuation Rectangulaire de 3¹⁄₄ xÉvacuation par le bas Vue arrière Montage du ventilateur à l’arrièreSortie par le côté gauche ou le côté droit Vue de faceRetirer les vis de la platine de montage du câble Achever l’installationClapet anti-retour de 3¹⁄₄ x 10 8,3 x 25,4 cm Raccord de transition rond de 6 15,2 cm avec clapetDéconnecter la source de courant électrique Raccordements électriquesÔter les 4 vis du couvercle du boîtier de connexion Serrer les vis des pieds de soutienContrôle du fonctionnement AvertissementConfiguration en îlot- Évacuation par l’arrière Instructions D’INSTALLATION Ventilateur Monté À L’EXTÉRIEURConfiguration avec encastrement Configuration en îlot- Évacuation par l’avantÉvacuation par l’avant ou par l’arrière Préparation du montage du système de ventilation en ligne Achever l’installation Ventilateur monté à l’extérieurCôté entrée Installation du système de ventilation en lignePréparation du système de ventilation en ligne Côté sortieSuffisamment de conduit de câblage de ¹⁄₂ 1,3 cm pour Installer les connecteurs de conduit et le conduit dans lesDe conduit de ¹⁄₂ 1,3 cm homologués UL ou CSA Conduit de câblage de ¹⁄₂ 1,3 cm entre le logement duConduit de câblage ¹⁄₂ 1,3 cm Homologation UL Par le bas Lorsque la cuisson est terminée Utilisation DU Système D’EXTRACTIONUtilisation du système d’extraction par le bas UtilisationSurface du système d’extraction par le bas Entretien DU Système D’ÉVACUATIONVentilateur monté à lintérieur Schéma DE CâblageVentilateur monté à lextérieur SEL0016521Au Canada Assistance OU ServiceAccessoires Aux États-UnisComposer le 1-800-422-1230. Au Canada, composer le Garantie DU Système DE Ventilation KitchenaidLa présente garantie limitée ne couvre pas W10342489E