INSTALLATION INSTRUCTIONS
TECHNICAL DATA
Gas connection | Rp ½ (½" BSP female) |
Pressure test point | Front left hotplate injector |
Gas rate adjustment | None |
Aeration adjustment | None |
Electrical connection | 4mm2 twin and earth |
| 230/240V a.c. 50Hz. |
CH60DPCF S CH60DPXF S |
|
|
|
| |
|
|
|
|
| |
| HEAT INPUT | INJECTOR | HEAT INPUT | INJECTOR | |
|
|
|
|
| |
HOTPLATE | 4.1 kW | 100+72+100 | 3.8 kW (275g/h) | 63+42+63 | |
Front Left | |||||
|
|
|
| ||
|
|
|
|
| |
HOTPLATE | 3.05 kW | 116 | 3.0 kW (220g/h) | 86 | |
Rear Right | |||||
|
|
|
| ||
|
|
|
|
| |
HOTPLATE | 2.0 kW | 103 | 2.0 kW (145g/h) | 70 | |
Front Right and Rear Left | |||||
|
|
|
| ||
|
|
|
|
| |
TOTAL LOAD |
| 4.5 / 4.9 kW |
| ||
|
|
|
|
| |
|
|
|
|
| |
CH60DTXF S S CH60DTCF S |
|
|
|
| |
| HEAT INPUT | INJECTOR | HEAT INPUT | INJECTOR | |
|
|
|
|
| |
HOTPLATE | 3.05 kW | 116 | 3.0 kW (220g/h) | 86 | |
Front Left and Rear Right | |||||
|
|
|
| ||
|
|
|
|
| |
HOTPLATE | 2.0 kW | 103 | 2.0 kW (145g/h) | 70 | |
Front Right and Rear Left | |||||
|
|
|
| ||
|
|
|
|
| |
TOTAL LOAD |
| 4.5 / 4.9 kW |
| ||
|
|
|
|
|
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
8