Henny Penny 342 manual Filter Switch Replacement

Page 12

Model OFE/OFG/OEA/OGA-341, 342

2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should

REPLACEMENT “open”, cutting off the pilot flame. This will prevent the fryer from heating while shortening is being drained from the frypot.

1.Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.The following check should be made to determine if the drain microswitch is defective.

a. Remove the two screws and nuts securing the microswitch

Figure 2-32to the drain rod valve bracket, and remove microswitch. Figure 2-32.

b.Remove wires from the switch. Figure 2-33.

c.Check for continuity across the two outside terminals of the drain switch. If the circuit is open, the drain switch is defective. The circuit opens by pressing on the actuator of the microswitch.

3.If defective, replace switch in reverse order.

Figure 2-33

2-14. FILTER SWITCH

 

REPLACEMENT

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Figure 2-34

2. Open the door (left door on 2 well units), and remove the 2

screws securing the switch box cover. Figure 2-34.

2-12

1003

Image 12
Contents Maintenance Hints High Temperature Limit ControlIntroduction Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketCapillary line under and away from all electrical power Wires and terminals. The tube must never be in such aPosition where it could accidentally touch the electrical Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Replacement Boards ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Checkout Power Removed HeatingContactors 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 High Temperature Connect the two electrical wiresLimit Control Electric Line under and away from all electrical power wires Where it could accidentally touch the electrical powerTerminals. The tube must never be in such a position TerminalsMotor Removal Transformer Replacement Filter Pump and Motor RemovalAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order