Henny Penny Comprehensive Guide to OFE 342 Fryer Maintenance Procedures

Page 27

Model OFE/OFG/OEA/OGA-341, 342

2-21. FILTER PUMP AND MOTOR REMOVAL (Continued)

7. Remove left side panel.

 

8.

Using 9/16” socket or wrenches, remove the bolts and nuts

 

 

securing the motor to the bracket and pull pump, motor, and

 

 

piping from unit. Figure 2-74.

Figure 2-74

 

 

2-22. AUTOLIFT

1.

Remove electrical power supplied to unit.

TRANSFORMER

 

 

REPLACEMENT

 

 

(if applicable)

 

 

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

 

 

breaker, or unplug cord at wall receptacle.

 

2.

Remove control panel.

 

3.

Label and remove wires from transformer. Figure 2-75.

Figure 2-75

4.Using 3/8” nut-driver or wrench, remove nuts securing transformer to panel and remove transformer from panel. Figure 2-76.

5.Install new transformer in reverse order.

Figure 2-76

1003

2-27

Image 27
Contents Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionRemove the high limit from bracket Remove the two screws securing the high limit to the bracketPower terminals Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Position where it could accidentally touch the electricalPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Replacement Boards ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold 30 31 34 35 36 Figure Checkout Power RemovedHeating ContactorsRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 High Temperature Connect the two electrical wiresLimit Control Electric Terminals Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Terminals. The tube must never be in such a positionMotor Removal Transformer Replacement Filter Pump and Motor RemovalAutolift If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order