Model OFE/OFG/OEA/OGA-341, 342

2-18. HEATING

Each well of an electric fryer requires two switching contactors.

CONTACTORS

The first in line is the primary contactor and the second in line is

(ELECTRIC)

the heat contactor. When open, the primary contactor does not

 

allow power to flow to the heat contactor. When closed, the

 

primary supplies voltage to the heat contactor. When the heat

 

contactor is open, no voltage is supplied to the heating elements.

 

When the heat contactor closes, voltage is supplied to the heating

 

elements.

Checkout (Power Removed)

1. Remove electrical power supplied to frypot to be worked on.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other control on 2-frypot

Heat Contactorunits will have power. (Mercury)

3031 32

33

37

34 35 36 Figure 2-52

2.Remove the control panel.

3.Perform a check on the contactor as follows:

Test Points

Results

From 23 to 29

open circuit

From 24 to 28

open circuit

From 25 to 27

open circuit

From 30 to 34

open circuit

From 31 to 35

open circuit

From 32 to 36

open circuit

From 33 to 37

ohm reading 1700

From 22 to 26

ohm reading 415

Wires should be removed and labeled to obtain an accurate check of contactors.

Figure 2-53

1003

2-19

Image 19
Contents Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionRemove the high limit from bracket Remove the two screws securing the high limit to the bracketPower terminals Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Position where it could accidentally touch the electricalPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Boards Replacement ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold 30 31 34 35 36 Figure Checkout Power RemovedHeating ContactorsRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 Connect the two electrical wires High TemperatureLimit Control Electric Terminals Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Terminals. The tube must never be in such a positionMotor Removal Filter Pump and Motor Removal Transformer ReplacementAutolift If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order