Model OFE/OFG/OEA/OGA-341, 342

2-6. TEMPERATURE PROBE 5. Remove the probe from the frypot, and disconnect wire

REPLACEMENT (GAS) connector from the control panel. Figure 2-15.

(Continued)

6.Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends one (1) inch (2.54cm) into the frypot. Figure 2-16.

7.Tighten hand tight and then a half turn with wrench.

Figure 2-15

Excess force will damage probe.

8.Connect new probe to PC board and replace control panel.

9.Replace shortening, and turn power on to check out fryer.

Figure 2-16

2-7. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature

REPLACEMENT (Gas) to the control board. If it becomes disabled, “E06” shows in the

REPLACEMENTdisplay. Also, if the shortening temperature is out of calibration

(ELECTRIC)more than 10°F or C°, the probe should be replaced. An Ohm check can also be performed. See chart on page 2-5.

1.Remove electrical power supplied to the fryer.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Drain the shortening from the frypot.

Figure 2-173. Remove screws securing rear cover of fryer, and remove rear cover. Figure 2-17.

2-6

1209

Image 6
Contents Introduction Maintenance HintsHigh Temperature Limit Control Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketPosition where it could accidentally touch the electrical Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Replacement Boards ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Contactors Checkout Power RemovedHeating 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 High Temperature Connect the two electrical wiresLimit Control Electric Terminals. The tube must never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power TerminalsMotor Removal Transformer Replacement Filter Pump and Motor RemovalAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order