Henny Penny 342 manual Speaker Assembly, To avoid electrical shock or property damage, move

Page 22

 

 

Model OFE/OFG/OEA/OGA-341, 342

2-19. SPEAKER ASSEMBLY

The speaker assembly emits audible signals to let the operator

 

know when cooking and hold times are finished.

 

1.

Remove electrical power supplied to unit.

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

Figure 2-58

 

breaker, or unplug cord at wall receptacle.

 

2.

Remove control panel.

 

3.

Pull the power switch connector from back of panel.

 

 

Figure 2-58.

Figure 2-59

 

 

 

4.

Pull the transformer connectors from back of panel.

 

 

Figure 2-59.

Figure 2-60

5.

Using a 5/16” nutdriver or wrench, remove the 4 nuts securing

 

 

the PC board shield and pull shield from studs. Figure 2-60.

 

6.

Pull the speaker connector from control board. Figure 2-61.

Figure 2-61

7.Using a 5/16” nut-driver or wrench, remove the 2 nuts securing the speaker to the shield and remove speaker from panel. Figure 2-62

8.Install new speaker in reverse order.

Figure 2-62

2-22

1003

Image 22
Contents Introduction Maintenance HintsHigh Temperature Limit Control Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketPosition where it could accidentally touch the electrical Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Boards Replacement ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Contactors Checkout Power RemovedHeating 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 Connect the two electrical wires High TemperatureLimit Control Electric Terminals. The tube must never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power TerminalsMotor Removal Filter Pump and Motor Removal Transformer ReplacementAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order