10-5 Save Changes
The
Some settings, though, require you to restart the Switch before they will take effect. Restarting the Switch erases all settings in RAM and reloads the stored settings from the
To retain any configuration changes permanently, click on the Save button in the Save Changes page, as shown below.
Figure 10- 8. Save Changes Screen
The Switch has three levels of save, which are as follows:
Parameter | Description |
Save (Only save config) | Clicking the radio button for this entry will save only the current switch configuration to |
Save Log (Only save log) | Clicking the radio button for this entry will save only the current current log file to NV- RAM. |
Save All (Save config and log) Clicking the radio button for this entry will save both the current switch configuration and the current log file to
These settings will be used every time the Switch is rebooted. See the Reset section for more information on changing configurations saved to
10-6 Reset
The Reset function has several options when resetting the Switch. Some of the current configuration parameters can be retained while resetting all other configuration parameters to their factory defaults.
Note: Only the Reset System option will enter the factory default parameters into the Switch’s
Figure 10- 9. Factory Reset to Default Value window
Allied Telesyn | 188 |