Figure 9- 24.Authenticator Statistics window
The user can specify a switch in a switch stack using that switch’s Unit ID by using the pull down menu in the top left hand corner.The user may also select the desired time interval to update the statistics, between 1s and 60s, where “s” stands for seconds.The default value is one second.
The following fields can be viewed:
Parameter | Description |
|
Port | The identification number assigned to the Port by the System in which the Port resides. | |
Frames Rx | The number of valid EAPOL frames that have been received by this Authenticator. | |
Frames Tx | The number of EAPOL frames that have been transmitted by this Authenticator. | |
Rx Start | The number of EAPOL Start frames that have been received by this Authenticator. | |
TxReqId | The number of EAP Req/Id frames that have been transmitted by this Authenticator. | |
RxLogOff | The number of EAPOL Logoff frames that have been received by this Authenticator. | |
Tx Req | The number of EAP Request frames (other than Rq/Id frames) that have been transmitted by this | |
Rx RespId | Authenticator. | |
The number of EAP Resp/Id frames that have been received by this Authenticator. | ||
Rx Resp | The number of valid EAP Response frames (other than Resp/Id frames) that have been received by this | |
Rx Invalid | Authenticator. | |
The number of EAPOL frames that have been received by this Authenticator in which the frame type is not | ||
Rx Error | recognized. | |
The number of EAPOL frames that have been received by this Authenticator in which the Packet Body Length | ||
Last Version | field is invalid. | |
The protocol version number carried in the most recently received EAPOL frame. | ||
Last Source | The source MAC address carried in the most recently received EAPOL frame. |
|
Allied Telesyn | 173 |