3.After changing the route preference value for a specific routing protocol, that protocol needs to be restarted because the previously learned routes have been dropped from the Switch.The Switch must learn the routes again before the new settings can take effect.

To view the Route Preference Settings window, click Configuration > Layer 3 IP Networking > Route Preference Settings:

 

 

Figure 6- 92. Current and New Route Preference Settings window

The following fields can be viewed or set:

 

 

 

Parameter

Description

 

 

RIP (1-999)

Enter a value between 1 and 999 to set the route preference for RIP.The lower the value, the higher the chance

 

OSPF Intra (1-999)

the specified protocol will be chosen as the best path for routing packets.The default value is 100.

 

Enter a value between 1 and 999 to set the route preference for OSPF Intra.The lower the value, the higher the

 

STATIC (1-999)

chance the specified protocol will be chosen as the best path for routing packets.The default value is 80.

 

Enter a value between 1 and 999 to set the route preference for Static.The lower the value, the higher the

 

OSPF Inter (1-999)

chance the specified protocol will be chosen as the best path for routing packets.The default value is 60.

 

Enter a value between 1 and 999 to set the route preference for OSPF Inter.The lower the value, the higher the

 

OSPF ExtT1 (1-999)

chance the specified protocol will be chosen as the best path for routing packets.The default value is 90.

 

Enter a value between 1 and 999 to set the route preference for OSPF ExtT1.The lower the value, the higher

 

OSPF ExtT2 (1-999)

the chance the specified protocol will be chosen as the best path for routing packets.The default value is 110.

 

Enter a value between 1 and 999 to set the route preference for OSPF ExtT2.The lower the value, the higher

 

 

the chance the specified protocol will be chosen as the best path for routing packets.The default value is 115.

 

 

 

 

Click Apply to implement changes made.

 

 