Model OFE/OFG/OEA/OGA-341, 342

2-20. HIGH TEMPERATURE This high temperature control is a safety, manual reset control,

LIMIT CONTROL which senses the temperature of the shortening. If the short-

(ELECTRIC)ening temperature exceeds 425°F (218°C), this switch opens and shuts off heat to the frypot, and E10 shows in control display. When the temperature of the shortening drops to a safe operation reset the high limit by pressing the reset button. The reset button is located behind the frypot, in the element hinge. A small instrument, such as a Phillip’s head screwdriver, or Allen wrench must be used to reset the high limit. This allows heat to be supplied to the frypot once again. See Figure 2-63.

Before replacing a high temperature limit control, check to see that its circuit is closed.

Figure 2-63

The shortening temperature must be below 380°F (193°C) to accurately perform this check.

1. Remove electrical power supplied to fryer.

Checkout

To avoid electrical shock or property damage, move the

 

power switch to OFF and disconnect main circuit

 

breaker, or unplug cord at wall receptacle.

2. Remove rear cover of fryer. Figure 2-64.

Figure 2-64

3.Remove the two screws securing the high limit to the bracket and pull high limit from bracket. Figure 2-65.

Figure 2-65

106

2-23

Image 23
Contents Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionRemove the high limit from bracket Remove the two screws securing the high limit to the bracketPower terminals Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Position where it could accidentally touch the electricalPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Transformer ReplacementBoards Replacement To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold 30 31 34 35 36 Figure Checkout Power RemovedHeating ContactorsRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 Limit Control Electric High TemperatureConnect the two electrical wires Terminals Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Terminals. The tube must never be in such a positionMotor Removal Autolift Transformer ReplacementFilter Pump and Motor Removal If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order