Henny Penny 342 manual Blower Motor Replacement, Heating Elements Electric

Page 17

Model OFE/OFG/OEA/OGA-341, 342

2-16.

BLOWER MOTOR

 

 

REPLACEMENT

 

 

(Continued)

 

 

 

8. Using 3/8 inch nut driver, remove nuts securing blower to the

 

 

unit. Figure 2-48. Pull blower from unit.

 

Figure 2-48

9. Install new blower in reverse order.

2-17.

HEATING ELEMENTS

 

 

(ELECTRIC)

 

 

 

Heating elements are available for 208 and 230 voltage. Check

 

 

data plate to determine correct voltage.

 

Checkout

If the shortening temperature recovery is very slow or at a slower

 

 

rate than required, this may indicate defective heating element(s).

 

 

An ohmmeter quickly indicates if the elements are shorted or open.

 

 

1. Remove electrical power supplied to the frypot to be checked

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

 

 

breaker, or unplug cord at wall receptacle, to the frypot

 

Figure 2-49

to be worked on. Be aware the other control on 2-frypot

 

units will have power.

2.Remove rear cover. Figure 2-49.

3.Using a flat-head screwdriver, remove the appropriate wires from the terminal blocks. Figure 2-50.

Figure 2-50

106

2-17

Image 17
Contents High Temperature Limit Control Maintenance HintsIntroduction Gas UnitsRemove the high limit from bracket Remove the two screws securing the high limit to the bracketWires and terminals. The tube must never be in such a Capillary line under and away from all electrical powerPosition where it could accidentally touch the electrical Power terminalsPower Switch Power Switch Excess force will damage probe Flame SENSOR/ Pilot / Ignitor Assembly GAS Temperature Probe Replacement ElectricFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Transformer ReplacementBoards Replacement To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Heating Elements Electric Blower Motor ReplacementWire Nos Voltage Wattage Ohms cold Heating Checkout Power RemovedContactors 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Heating Contactors Electric Replacement Primary ContactorSpeaker Assembly 106 Limit Control Electric High TemperatureConnect the two electrical wires Where it could accidentally touch the electrical power Line under and away from all electrical power wiresTerminals. The tube must never be in such a position TerminalsMotor Removal Autolift Transformer ReplacementFilter Pump and Motor Removal If applicable Actuator Motor ReplacementAutolift Actuator Motor Replacement Install new actuator in reverse order