Henny Penny 342 manual Wire Nos Voltage Wattage Ohms cold, Replacement

Page 18

Model OFE/OFG/OEA/OGA-341, 342

2-17. HEATING ELEMENTS 4. Perform an ohm check on one element at a time, with wires

(ELECTRIC)

disconnected. The 2 elements actually have 3 small heating

(Continued)

elements inside the outer plate. It’s important to check

 

between the correct wires to obtain an accurate ohm reading.

 

The wires are labeled for your convenience. If the resistance

 

is not within tolerance, replace the element.

 

 

Wire Nos.

Voltage

Wattage

Ohms (cold)

 

1L1 to 1L1

208

11000

11.7

 

1L2 to 1L2

208

11000

11.7

 

1L3 to 1L3

208

11000

11.7

 

1L1 to 1L1

240

11000

15.7

 

1L2 to 1L2

240

11000

15.7

 

1L3 to 1L3

240

11000

15.7

Replacement

1.

Drain the shortening from the frypot

 

2.

Remove the high limit bulb holder from the heating

 

 

element inside the frypot. See High Limit Temperature

 

 

Control-Electric Section.

 

3.

Using a Phillip’s-head screwdriver, remove the screws

 

 

securing the element to the element hinges. Figure 2-51.

 

4.

Pull element from fryer and replace with new element,

 

 

following steps in reverse order.

Figure 2-51

5. Connect the power cord to the wall receptacle or close wall

 

circuit breaker.

Heating elements should never be energized without shortening in the frypot, or damage to the elements could result.

6.Replace the shortening in the frypot, and unit is ready for operation.

2-18

1003

Image 18
Contents Introduction Maintenance HintsHigh Temperature Limit Control Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketPosition where it could accidentally touch the electrical Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Replacement Boards ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Contactors Checkout Power RemovedHeating 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 High Temperature Connect the two electrical wiresLimit Control Electric Terminals. The tube must never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power TerminalsMotor Removal Transformer Replacement Filter Pump and Motor RemovalAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order