Henny Penny 342 manual High Temperature, Limit Control Electric, Connect the two electrical wires

Page 24

Model OFE/OFG/OEA/OGA-341, 342

2-20. HIGH TEMPERATURE

LIMIT CONTROL (ELECTRIC) (Continued)

4.Pull back cardboard cover and remove the two electrical wires from the high temperature limit control. Figure 2-66.

Figure 2-66

5. Manually reset the control, then check for continuity between

 

the two terminals after resetting the control. If the circuit is

 

open, replace the control, then continue with this procedure.

 

(If the circuit is closed, the high limit is not defective. Re-

 

connect the two electrical wires.)

Replacement

 

 

To avoid electrical shock or property damage, move the

 

power switch to OFF and disconnect main circuit

 

breaker, or unplug cord at wall receptacle, to the frypot

 

to be worked on. Be aware the other control on 2-frypot

 

units will have power.

 

1. Drain the shortening from the frypot.

Figure 2-67

2.Remove capillary from brackets on upper part of element. Figure 2-67.

3.Remove capillary bulb from bulb holder inside the frypot.

Figure 2-68

2-24

1003

Image 24
Contents Maintenance Hints High Temperature Limit ControlIntroduction Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketCapillary line under and away from all electrical power Wires and terminals. The tube must never be in such aPosition where it could accidentally touch the electrical Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Replacement Boards ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Checkout Power Removed HeatingContactors 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 High Temperature Connect the two electrical wiresLimit Control Electric Line under and away from all electrical power wires Where it could accidentally touch the electrical powerTerminals. The tube must never be in such a position TerminalsMotor Removal Transformer Replacement Filter Pump and Motor RemovalAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order