Henny Penny 342 manual Motor Removal

Page 26

Model OFE/OFG/OEA/OGA-341, 342

2-21. FILTER PUMP AND 1. Remove electrical power supplied to unit.

MOTOR REMOVAL

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Open the door (left door on 2 well units), and remove the 2 screws securing the switch box cover and pull filter motor wires from filter switch. Figure 2-70.

Figure 2-70

3.Remove the 2 screws securing the switch box to the frame. Figure 2-71

Figure 2-71

4.Loosen screws on conduit connector and pull conduit from the connector. Figure 2-72.

5.Disconnect filter union to filter in drain pan.

Figure 2-72

6.Using a pipe wrench, disconnect the outlet pipe to frypot. Figure 2-73.

Figure 2-73

2-26

1003

Image 26
Contents Introduction Maintenance HintsHigh Temperature Limit Control Gas UnitsRemove the two screws securing the high limit to the bracket Remove the high limit from bracketPosition where it could accidentally touch the electrical Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Power terminalsPower Switch Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Transformer ReplacementBoards Replacement To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Contactors Checkout Power RemovedHeating 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 Limit Control Electric High TemperatureConnect the two electrical wires Terminals. The tube must never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power TerminalsMotor Removal Autolift Transformer ReplacementFilter Pump and Motor Removal Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order