c)WV and HGV Diagnosis: If WV is energized, check for 115VAC at CB K1 #6 (O) to neutral (W). If 115VAC is present after PM energizes in harvest cycle, replace CB. If 115VAC is not present, replace WV (bypassing). If HGV did not deenergize at the end of harvest, check for 115VAC at CB K1 #2 (P) to neutral (W). If 115VAC is present 50 sec. after PM energizes, replace CB. If 115VAC is not present, replace HGV (bypassing).

d)PM Diagnosis: Confirm water is flowing over evaporator from PM and not WV. If PM de-energizes once freeze begins, check for 115VAC at CB K1 #4 (R) to neutral (W). If 115VAC is not present, replace CB. If 115VAC is present and PM is de-energized, check for 115VAC at control switch #5 (R) to neutral (W). If 115VAC is present at CB K1 #4 (R) and not at control switch #5 (R), check control switch continuity between #5 (R) and #4 (R). Replace as needed. If 115VAC is present at control switch #5 (R) to neutral (W), check PM capacitor and motor winding continuity.

e)FM and LLV Diagnosis: If FM or LLV does not energize, check for 115VAC at CB

K1 #3 (BK) to neutral (W). If 115VAC is not present, replace CB. If 115VAC is present: For FM, check capacitor, motor winding, and blade for binding.

For LLV, check coil voltage and continuity.

f)Refrigerant Pressures, HM, and TXV Diagnosis: If evaporator is still not cooling, check refrigerant pressures. See "VIII.A. Specification and Performance Data." Next, check HM operation. If refrigeration pressures are above HM setpoint and HM is bypassing, replace HM. Check TXV for proper operation. Remove TXV bulb and hold it in your hand, refrigerant low-side pressure should rise, place TXV bulb in ice water, refrigerant low-side pressure should drop. A 10 to 15 pound pressure swing between warm and cold conditions indicate a good TXV. If a 10 to 15 pound swing is not present, replace TXV.

g)WRV Diagnosis: WRV is factory set and generally no adjustment is required.

If WRV fails to open in freeze, check for proper refrigerant pressures. See "VIII.A. Specification and Performance Data." If refrigerant pressures are correct and WRV does not open, adjust or replace as needed. See "IV.C. Water Regulating Valve Adjustment (watercooled models)."

h)Freeze Termination Diagnosis: After 5 min. in freeze, disconnect CB K5 FS connector. 15 sec. later appliance should switch out of the freeze cycle (15 second delay after FS opens before terminating the freeze cycle). If appliance remains in freeze longer than 15 sec. after FS removed, replace CB. If appliance switches with FS removed but would previously not switch out of freeze with FS connected (long freeze - 3 beep alarm), see "II.E. Float Switch Check and Cleaning."

Note: Normal freeze cycle will last 20 to 40 min. depending on model and conditions. Cycle times and pressures should follow performance data provided in this manual. See "VIII.A. Specification and Performance Data."

i)Short Freeze Cycle Diagnosis: Confirm water tank fills and overflows during 1 min. fill and harvest cycles. If not, check water supply filters, shut-off valve, WV screen. If water tank empties before 5 min. timer terminates and freeze cycle is short, check that CV is not leaking by (water flowing down the potable drain). If CV is leaking by, remove and clean CV, replace rubber seat and spring if necessary. If water tank is full, see "II.E. Float Switch Check and Cleaning." for erratic FS.

28

Image 28
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page 100 Important Safety Information Additional Warning for Remote Models Air-Cooled Models SAH/3 Model Shown KM-1301SAH3Water-Cooled Models SWH/3/-M Model Shown KM-1301SWH3Remote Models SRH/3 Model Shown KM-1301SRH3Water-Cooled Models SWH/3 KMH ConstructionModel Shown KMH-2000SWH3 Model Shown KMH-2000SRH3 Diagram Water TankWater Supply KM-2500SRH3 Water Shutdown Bin Full Icemaker Off Ice Level Lowered Restart Sequence of Operation Flow ChartTo 1 -Minute Fill Cycle Control Board with Harvest Pump Timer Operation Harvest Pump Timer StartupService Diagnosis G Control Board without Harvest Pump Timer Diagnosis Page Page OFF Shutdown E and G Control Board Control Board with Harvest Pump Timer Diagnosis Page Page Page Every cycle After 2nd freeze cycle Shutdown G Control Board Control Board Check Control Correct LED Board Lighting SequenceBin Control Check Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check No Ice Production Diagnostic TablesNo Ice Production Possible Cause Freeze-Up Freeze-Up Possible Cause Harvest CycleLow Ice Production Freeze-Up Possible CauseFreeze Cycle Low Ice Production Possible Cause Long Harvest CycleLow Ice Production Possible Cause Long Freeze Cycle III. Controls and Adjustments Control Board Control Board LayoutControl Board Bin Control Switch Open LED yellow Part Number Alarm BuzzerK2 Connector S5 Dip Switch K5 black ConnectorLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Settings and Adjustments Default Dip Switch SettingsS5 Dip Switch S4 Dip Switch G Control BoardsHarvest Timer S4 dip switch 1 S4 Dip Switch Setting Time sec Inlet Water Pump-Out Timer S4 dip switch 3Valve Pump-Out Frequency Control S4 dip switch 5 Control Board 1st Pump-Out S4 Dip Switch Setting FrequencyS4 Dip Switch Setting Control BoardFactory Use S4 dip switch Freeze Timer S4 dip switch 9Control Board S4 Dip Switch Setting Pump Motor Time sec S4 Dip Switch Setting Time MinFloat Switch Selector S5 dip switch 1 G Control Board Control SwitchRefill Counter S5 dip switch 2 through 5 G Control Board Refrigeration Circuit Service Information IV. Refrigeration Circuit and Component Service InformationRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Component Service Information ComponentWater Regulating Valve Adjustment water-cooled models Maintenance Schedule MaintenanceFrequency Area Task Remove the water from the icemaker water supply line VI. Preparing the Icemaker for Periods of Non-UseDrain the water tank Page VII. Disposal VIII. Technical Information Specification and Performance DataKM-1301SAH KM-1301SAH3 KM-1301SWH Electric & Water ConsumptionKM-1301SWH3 1770237 240KM-1301SRH with URC-14F KM-1301SRH3 with URC-14F 463192 214KM-1400SWH-M KM-1400SWH3-M 17001720 230KM-1601SAH 14622450 2281456 KM-1601SAH32610 241 KM-1601SWH257 KM-1601SWH3 12.8 a 5 Min. Freeze AT 104F/WT 80F 375 785213 KM-1601SRH with URC-22F Auxiliary Codes S-2 and Later 755352 207202 504247 781 KM-1601SRH3 with URC-22F Auxiliary Codes S-2 and Later KM-1900SAH 2480KM-1900SAH3 1859KM-1900SWH 18761850 1650KM-1900SWH3 18142137 239KM-1900SRH with URC-21F KM-1900SRH with URC-22F 18572500 328KM-1900SRH3 with URC-21F 19652680 332KM-1900SRH3 with URC-22F 2096 KM-2100SWH31794 KM-2100SRH3 with URC-22F 3210382 2702408 KM-2500SWH32174 KM-2500SRH3 with URC-23F 3780KMH-2000SWH 18212410 1464KMH-2000SWH3 KMH-2000SRH with URC-22F 19442570 307KMH-2000SRH3 with URC-22F Wiring Diagrams KM-1601SWH, KM-1601SRH, KM-1900SH, KMH-2000SHKM-2500SH3, KMH-2000SH3 Diagrams with Harvest Pump Timer Relays G Control Board Auxiliary CodeKM-1301SH3 Auxiliary Code T-0, U-0 KM-1301SH Auxiliary Code U-1 and Later and KM-1601SAH KM-1301SH3 Auxiliary Code U-1 and Later and KM-1601SAH3 KM-1400SWH-M KM-1400SWH3-M