Hoshizaki SWH3-M KM-1601SAH/3, SRH/3 KM-2100SWH3, SRH/3 KM-1400SWH-M Shutdown G Control Board

Page 30

8)Normal Harvest Cycle – Same as the initial harvest cycle. Return to step 5a) above. Note: Appliance continues to cycle until MBC is satisfied or power is switched off. The

appliance always restarts at the 1-min. fill cycle.

9)Shutdown: "G" Control Board

When the appliance is running, hold ice in contact with the thermostatic bulb. BC switch opens within 10 sec., shutting down the appliance. BC is factory set, and generally no adjustment is required. However, adjustment may be needed in some conditions, particularly at higher altitude locations. CB red K4 connector must have the jumper in place. When the jumper is in place, the green "BC CLOSED" LED remains on. If the jumper is not in place, yellow "BC OPEN" LED turns on and the icemaker turns off and remains off until the jumper is replaced in its original position. Diagnosis: See "II.D. Bin Control Check."

Legend: BC–bin control; CB–control board; Comp–compressor; CR–compressor relay; CT–control transformer; CV–check valve; FM–fan motor; FMR–fan motor remote; FS–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); HPS–high-pressure switch; LLV–liquid line valve; MC–magnetic contactor; PM–pump motor; TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet water valve

30

Image 30
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page 100 Important Safety Information Additional Warning for Remote Models Air-Cooled Models SAH/3 Model Shown KM-1301SAH3Water-Cooled Models SWH/3/-M Model Shown KM-1301SWH3Remote Models SRH/3 Model Shown KM-1301SRH3KMH Construction Water-Cooled Models SWH/3Model Shown KMH-2000SWH3 Model Shown KMH-2000SRH3 Diagram Water TankWater Supply KM-2500SRH3 Water Sequence of Operation Flow Chart Shutdown Bin Full Icemaker Off Ice Level Lowered RestartTo 1 -Minute Fill Cycle Control Board with Harvest Pump Timer Operation Harvest Pump Timer StartupService Diagnosis G Control Board without Harvest Pump Timer Diagnosis Page Page OFF Shutdown E and G Control Board Control Board with Harvest Pump Timer Diagnosis Page Page Page Every cycle After 2nd freeze cycle Shutdown G Control Board Control Board Check Control Correct LED Board Lighting SequenceBin Control Check Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Diagnostic Tables No Ice ProductionNo Ice Production Possible Cause Freeze-Up Freeze-Up Possible Cause Harvest CycleFreeze Cycle Low Ice ProductionFreeze-Up Possible Cause Low Ice Production Possible Cause Long Harvest CycleLow Ice Production Possible Cause Long Freeze Cycle III. Controls and Adjustments Control Board Layout Control BoardControl Board K2 Connector Bin Control Switch Open LED yellowPart Number Alarm Buzzer S5 Dip Switch K5 black ConnectorSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Energized Time LEDs are On Components Min Max AvgControl Board Settings and Adjustments Default Dip Switch SettingsS4 Dip Switch G Control Boards S5 Dip SwitchHarvest Timer S4 dip switch 1 Pump-Out Timer S4 dip switch 3 S4 Dip Switch Setting Time sec Inlet WaterValve S4 Dip Switch Setting Pump-Out Frequency Control S4 dip switch 5Control Board 1st Pump-Out S4 Dip Switch Setting Frequency Control BoardControl Board S4 Dip Switch Setting Pump Motor Time sec Factory Use S4 dip switchFreeze Timer S4 dip switch 9 S4 Dip Switch Setting Time MinControl Switch Float Switch Selector S5 dip switch 1 G Control BoardRefill Counter S5 dip switch 2 through 5 G Control Board IV. Refrigeration Circuit and Component Service Information Refrigeration Circuit Service InformationRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Component Service Information ComponentWater Regulating Valve Adjustment water-cooled models Maintenance Maintenance ScheduleFrequency Area Task VI. Preparing the Icemaker for Periods of Non-Use Remove the water from the icemaker water supply lineDrain the water tank Page VII. Disposal Specification and Performance Data VIII. Technical InformationKM-1301SAH KM-1301SAH3 KM-1301SWH Electric & Water Consumption237 KM-1301SWH31770 240KM-1301SRH with URC-14F 192 KM-1301SRH3 with URC-14F463 214KM-1400SWH-M 1720 KM-1400SWH3-M1700 2302450 KM-1601SAH1462 228KM-1601SAH3 14562610 KM-1601SWH 241257 KM-1601SWH3 12.8 a 5 Min. Freeze AT 104F/WT 80F 785 375213 352 KM-1601SRH with URC-22F Auxiliary Codes S-2 and Later755 207504 202247 781 KM-1601SRH3 with URC-22F Auxiliary Codes S-2 and Later KM-1900SAH 2480KM-1900SAH3 18591850 KM-1900SWH1876 16502137 KM-1900SWH31814 239KM-1900SRH with URC-21F 2500 KM-1900SRH with URC-22F1857 3282680 KM-1900SRH3 with URC-21F1965 332KM-1900SRH3 with URC-22F KM-2100SWH3 20961794 382 KM-2100SRH3 with URC-22F3210 270KM-2500SWH3 24082174 KM-2500SRH3 with URC-23F 37802410 KMH-2000SWH1821 1464KMH-2000SWH3 2570 KMH-2000SRH with URC-22F1944 307KMH-2000SRH3 with URC-22F Wiring Diagrams KM-1601SWH, KM-1601SRH, KM-1900SH, KMH-2000SHKM-2500SH3, KMH-2000SH3 Diagrams with Harvest Pump Timer Relays G Control Board Auxiliary CodeKM-1301SH3 Auxiliary Code T-0, U-0 KM-1301SH Auxiliary Code U-1 and Later and KM-1601SAH KM-1301SH3 Auxiliary Code U-1 and Later and KM-1601SAH3 KM-1400SWH-M KM-1400SWH3-M
Related manuals
Manual 84 pages 2.34 Kb

SRH/3 KM-1900SAH/3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3, SWH/3, KM-1301SAH/3 specifications

The Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 are advanced ice makers designed for commercial use, addressing a wide variety of needs in restaurants, hotels, and bars. These models are known for their efficiency, durability, and innovative technologies that ensure the production of high-quality ice.

One of the standout features of these units is their ability to produce a high volume of ice, reaching up to 1,300 pounds per day, which is crucial for establishments with heavy ice demands. The machines utilize advanced cooling technology, allowing for faster ice production and minimizing the time required to refill ice bins. This makes them ideal for busy settings where speed and efficiency are paramount.

The KM-1301 series employs a unique stainless steel exterior that not only ensures longevity and resistance to corrosion but also enhances the aesthetic appeal of any commercial kitchen or bar. The interior is designed for easy cleaning, helping to maintain hygiene standards vital for food safety.

These ice makers utilize the proprietary Hoshizaki Cubelet Ice system, producing small, chewy ice cubes that are perfect for various beverages and food displays. The advanced design of the ice-making mechanism ensures that ice is formed quickly and efficiently, reducing energy consumption. Additionally, Hoshizaki’s CycleSaver technology optimizes the production process by reducing the amount of water used, making these machines environmentally friendly.

Another characteristic is their self-diagnostic capability, which allows for real-time monitoring of unit performance and quicker troubleshooting, minimizing downtime. The built-in alerts notify operators of any issues or maintenance needs, ensuring that the ice-making process remains uninterrupted.

The KM-1301 series also provides user-friendly controls that allow easy adjustments and monitoring of ice production settings. This flexibility enables businesses to meet varying ice demands based on seasonality or special events.

In summary, the Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 ice makers are exemplary choices for commercial ice production. With their high output, durable design, energy efficiency, innovative technologies, and user-friendly features, they cater effectively to the rigorous demands of the foodservice industry while maintaining a commitment to quality and sustainability.