Problem | Possible Cause |
| Remedy |
|
|
|
|
[1] The icemaker will | m)High Pressure Switch | 1. Bad contacts. | 1. Check for continuity and |
not start. (Fill Cycle) |
|
| replace. |
(continued) |
|
|
|
| 2. Dirty air filter or | 2. Clean. | |
|
| ||
|
| condenser. |
|
|
| 3. Ambient or condenser | 3. Reduce temperature. |
|
| water temperature too |
|
|
| warm. |
|
|
|
|
|
|
| 4. Refrigerant | 4. Recover, evacuate, and |
|
| overcharged. | recharge. |
|
|
|
|
|
| 5. Fan not operating | 5. See "3.[2]a) Fan Motor." |
|
| (except |
|
|
| model). |
|
|
|
|
|
|
| 6. Refrigerant line or | 6. Remove the restriction or |
|
| components restricted. | component and replace |
|
|
| the drier. |
|
| 7. Condenser water | 7. Check and get |
|
| pressure too low or off | recommended pressure. |
|
|
| |
|
| only). |
|
|
| 8. Water regulating | 8. Adjust it lower. |
|
| valve set too high |
|
|
| (water‑cooled model |
|
|
| only). |
|
|
|
|
|
| n) Plug and Receptacle | 1. Disconnected. | 1. Connect. |
| (Control Box) |
|
|
| 2. Loose terminal. | 2. Repair terminal | |
|
| ||
|
|
| connection. |
|
|
|
|
| o) Control Board | 1. Defective. | 1. See "II.D.4. Control Board |
|
|
| Check Procedure." |
[2] Fill cycle will not | a) Water Supply | 1. Water supply off or | 1. Check and get |
terminate. |
| pressure too low. | recommended pressure. |
|
|
|
|
| b) Float Switch | 1. Connector | 1. Reconnect. |
|
| disconnected. |
|
|
|
|
|
|
| 2. Float does not move | 2. Clean or replace. |
|
| freely. |
|
|
|
|
|
|
| 3. Defective switch. | 3. Check and replace. |
| c) Water Control Relay | 1. Contacts sticking. | 1. Replace. |
|
|
|
|
|
| 2. Coil winding open. | 2. Replace. |
|
|
|
|
| d) Drain Valve | 1. Valve seat won't seal | 1. Clean or replace. |
|
| and water leaking. |
|
|
|
|
|
| e) Hoses | 1. Disconnected or | 1. Reconnect or replace. |
|
| damaged. |
|
| f) Control Board | 1. Defective. | 1. See "II.D.4. Control Board |
|
|
| Check Procedure." |
|
|
|
|