C. Diagnostic Charts
1. No Ice Production
Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[1] The icemaker will not | a) Power Supply | 1. Off, blown fuse, or | 1. Turn on, replace, or reset. | |
start. (Fill Cycle) |
|
| tripped breaker. |
|
|
|
|
|
|
|
|
| 2. Loose connection. | 2. Tighten. |
|
|
| 3. Bad contacts. | 3. Check for continuity and |
|
|
|
| replace. |
|
|
|
|
|
|
|
| 4. Not within | 4. Refer to nameplate and |
|
|
| specifications. | correct. |
|
|
|
| |
| b) Water Supply | 1. Water supply off or | 1. Check and get | |
|
|
| pressure too low. | recommended pressure. |
|
|
|
| |
| c) Power Switch | 1. "OFF" position. | 1. Move to "ON" position. | |
|
| (Control Box) |
|
|
|
| 2. Bad contacts. | 2. Check for continuity and | |
|
|
| ||
|
|
|
| replace. |
| d) Door Switch | 1. Door switch not | 1. Engage door switch. | |
|
|
| engaged. |
|
|
|
|
|
|
|
|
| 2. Bad contacts. | 2. Check for continuity and |
|
|
|
| replace. |
|
|
|
| |
| e) Power Protect Relay | 1. Voltage not within | 1. Refer to nameplate and | |
|
|
| specifications. | correct. |
|
|
|
|
|
|
|
| 2. Bad contacts. | 2. Check for continuity and |
|
|
|
| replace. |
| f) | Transformer | 1. Coil winding open. | 1. Replace. |
|
|
|
| |
| g) Fuses (2) | 1. Blown. | 1. Check for short circuit and | |
|
|
|
| replace. |
|
|
|
| |
| h) Control Switch | 1. "OFF" or "DRAIN" | 1. Move to "ICE" position. | |
|
|
| position. |
|
|
|
|
|
|
|
|
| 2. Bad contacts. | 2. Check for continuity and |
|
|
|
| replace. |
| i) | Water Control Relay | 1. Bad contacts. | 1. Check for continuity and |
|
|
|
| replace. |
|
|
|
|
|
|
|
| 2. Coil winding open. | 2. Replace. |
|
|
|
|
|
| j) | Inlet Water Valve | 1. Mesh filter or orifice | 1. Clean. |
|
|
| clogged. |
|
|
|
|
|
|
|
|
| 2. Coil winding open. | 2. Replace. |
|
|
| 3. Wiring to inlet water | 3. Check for loose or open |
|
|
| valve. | connection. Repair or |
|
|
|
| replace. |
|
|
|
| |
| k) Float Switch | 1. Bad contacts. | 1. Check for continuity and | |
|
|
|
| replace. |
|
|
|
|
|
|
|
| 2. Float does not move | 2. Clean or replace. |
|
|
| freely. |
|
|
|
|
|
|
| l) | Bin Control | 1. Open. | 1. Bin full, check for |
|
|
|
| continuity on proximity |
|
|
|
| switch. |
|
|
| 2. Actuator sticking. | 2. Adjust or replace. |
|
|
|
|
|
|
|
| 3. Proximity switch open. | 3. Replace. |
|
|
|
|
|
38