Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[4] Gear motor overload | a)Power Supply | 1. Not within | 1. Refer to nameplate and | |
protector operates |
| specifications. | correct. | |
frequently or fuse | b)Evaporator Assembly | 1. Bearings or auger | 1. Replace bearings or | |
blows frequently. | ||||
| worn out. | auger. See "V.F.1. Upper | ||
|
| |||
|
|
| Bearing Wear Check." | |
|
|
|
| |
| c) Bin Control | 1. Bad contacts. | 1. Check for continuity and | |
|
|
| replace. | |
|
|
|
| |
|
| 2. Actuator does not | 2. Clean actuator or replace | |
|
| move freely. | bin control assembly. | |
|
|
|
| |
| d)Safety Switch and | 1. Switch misaligned, | 1. Check and correct or | |
| Relay | contacts bad. | replace. | |
| e)Control Board | 1. Erratic operation of | 1. See "II.D.4. Control Board | |
|
| gear motor relay. | Check Procedure." |
4. Dispensing
Problem | Possible Cause |
| Remedy |
|
|
|
|
[1] No ice dispensed. | a) Power Supply | 1. "OFF" position. | 1. Move to "ON" position. |
|
| 2. Loose connection. | 2. Tighten. |
|
| 3. Bad contacts. | 3. Check for continuity and |
|
|
| replace. |
|
| 4. Not within | 4. Refer to nameplate and |
|
| specifications. | correct. |
| b) Ice Storage | 1. No ice or little ice in | 1. Make ice. |
|
| storage bin. |
|
|
| 2. Ice bridge or ice block | 2. Melt ice, resupply with |
|
| formed. | new ice. |
|
| 3. Agitating motor | 3. Check, replace. |
|
| defective. |
|
|
|
|
|
| c) Ice Dispense Switch | 1. Opti Serve sensor | 1. See "5. Opti Serve (OS) |
|
| defective. (OS only) | Sensors." |
|
| 2. Bad contacts. (push | 2. Check for continuity and |
|
| button only) | replace. |
| d) Shutter Assembly | 1. Broken part. | 1. Check and replace. |
|
| 2. Open windings on | 2. Check continuity and |
|
| solenoid. | replace. |
| e) Dispense Gear Motor | 1. Thermal protector is | 1. Allow to cool. |
|
| tripped. |
|
|
| 2. Gear motor winding | 2. Replace. |
|
| open. |
|
|
| 3. Bearing worn out. | 3. Replace. |
|
| 4. Wiring to gear motor. | 4. Check for loose |
|
|
| connection or open |
|
|
| circuit, and replace wiring |
|
|
| as needed. |
|
| 5. Defective capacitor. | 5. Replace. |
| f) Auger Mechanism | 1. Bad alignment of | 1. Realign. |
|
| auger. |
|
| g) Control Board | 1. Defective. | 1. See "II.D.4. Control |
|
|
| Board Check Procedure." |
|
|
|
|
43