Hoshizaki Detailed Specifications for the Ice Maker KM-1301SWH

Page 10

SPECIFICATIONS

MODEL: URC-14FE

AC SUPPLY VOLTAGE

115/50/1 (Connection to Icemaker)

 

FAN MOTOR

115 V

Total 2.6FLA

130W

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

35-11/16"×15-11/16"×21-15/16" (907.2×398×557.8 mm)

DIMENSIONS INCLUDING LEGS (WxDxH)

37-13/16"×18-1/8"×36-15/16" (960×460×937.8 mm)

EXTERIOR FINISH

Galvanized Steel

 

 

 

 

WEIGHT

Net 80 lb. ( 36 kg ) Shipping 87 lb. ( 39 kg )

 

 

 

 

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

- REFRIGERANT

Discharge Line 1-1/16"-12 UNF Fitting (#10 PARKER)

 

Liquid Line 5/8"-18 UNF Fitting (#6 PARKER)

 

 

 

CONDENSER

Air-Cooled, Fin and Tube Type

 

FAN MOTOR PROTECTION

Thermal Protection

 

 

REFRIGERANT CONTROL

Headmaster (C.P.R.) (190 PSIG)

 

REFRIGERANT CHARGE

R-404A

4 lb. 6.5 oz.

(2000 g)

 

DESIGN PRESSURE

High 467 PSIG

32.2 Bar

 

 

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

104 ~ 127V

 

 

AMBIENT TEMP.

-20 ~ 122°F

 

 

 

 

 

 

ACCESSORIES -SUPPLIED

Leg

 

 

2 pcs

 

Hex Head Bolt w/Washer

8×16

8 pcs

 

Hex Nut

 

8

8 pcs

 

 

 

Note: We reserve the right to make changes in specifications

and design

without prior

notice.

 

 

 

 

10

Image 10
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Indicates important information about the use and care Important Safety InformationSerious injury UnitSpecifications Icemaker KM-1301SAH-E air-cooledKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled Condenser Unit URC-14FESpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Minute Fill Cycle Sequence of OperationSequence Cycles and Shutdown Initial Harvest CyclePump-Out Cycle S4 Dip Switch Setting Pump-Out 1st Pump-Out FrequencyFreeze Cycle Harvest CycleMechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Cycle at Shutdown Mechanical Bin Control ActivationPump-Out Cycle Sequence Flow ChartCycle Steps Minute Fill Harvest Cycle Mechanical BC Bin Full Shutdown and RestartControl Board Control Board Layout Control BoardSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Time LEDs are OnDefault Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 Pump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3Time seconds Inlet Freeze Timer S4 dip switch 9 Harvest Pump Timer S4 dip switchFactory Use S4 dip switch S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch Control SwitchRefill Counter S5 dip switch 2 through Tank Water Tank Headmaster Service Drier Valve Thermistor KM-1301SAH-E air-cooled Wiring DiagramsAuxiliary Code T-0, U-0 U-0 Auxiliary CodeAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1780 13301240 13351950 12701142 2070IV. Service Diagnosis Diagnostic ProcedurePage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Shutdown Thermostatic Bin Control KM-1301SAH-E Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-EControl Board Check Thermostatic Bin Control Check KM-1301SAH-E Bin Control CheckMechanical Bin Control Check Single Unit Connection Detail Stacked Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Adjustment of Water Regulating Valve water-cooled model Thermistor CheckNo Ice Production Diagnostic ChartsNo Ice Production Possible Cause No Ice Production Possible Cause Freeze Up Freeze Up Possible Cause Harvest CycleFreeze Up Possible Cause Freeze Cycle Low Ice Production Possible Cause Long Harvest Cycle Low Ice ProductionLong Freeze Cycle Service for Refrigerant Lines Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Important Notes for Component Replacement ComponentVI. Cleaning and Maintenance Cleaning ProcedureIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Maintenance Remove the water from the icemaker water supply lineDrain the water tank