C. Performance Data
1. KM-1301SAH-E (air-cooled)
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 |
| 1114 | 505 |
| 1082 | 491 |
| 992 | 450 |
|
|
|
| 80/27 |
| 1089 | 494 |
| 1039 | 471 |
| 924 | 419 |
lbs./day |
| kg./day |
| 90/32 |
| 1082 | 491 |
| 1004 | 455 |
| 897 | 407 |
|
| 100/38 |
| 1048 | 475 |
| 979 | 444 |
| 799 | 362 | ||
|
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
| 1900 |
|
|
| 1964 |
|
| 2009 | |||
CONSUMPTION | 80/27 |
| 1949 |
|
|
| 2049 |
|
| 2069 | |||
|
|
|
| 90/32 |
| 1964 |
|
|
| 2120 |
|
| 2151 |
watts |
|
|
| 100/38 |
| 1958 |
|
|
| 2127 |
|
| 2180 |
APPROXIMATE WATER | 70/21 |
| 537 | 2.03 |
| 426 | 1.61 |
| 377 | 1.43 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 452 | 1.71 |
| 279 | 1.06 |
| 288 | 1.09 | |||
|
| m3/day | 90/32 |
| 426 | 1.61 |
| 157 | 0.59 |
| 140 | 0.53 | |
gal./day |
| 100/38 |
| 302 | 1.14 |
| 153 | 0.58 |
| 125 | 0.47 | ||
FREEZING CYCLE TIME | 70/21 |
| 34 |
|
|
| 35 |
|
| 39 | |||
|
|
|
| 80/27 |
| 35 |
|
|
| 38 |
|
| 43 |
|
|
|
| 90/32 |
| 35 |
|
|
| 40 |
|
| 44 |
min. |
|
|
| 100/38 |
| 37 |
|
|
| 41 |
|
| 48 |
HARVEST CYCLE TIME | 70/21 |
| 4.8 |
|
|
| 4.0 |
|
| 3.7 | |||
|
|
|
| 80/27 |
| 4.2 |
|
|
| 2.9 |
|
| 3.2 |
|
|
|
| 90/32 |
| 4.0 |
|
|
| 2.1 |
|
| 2.1 |
min. |
|
|
| 100/38 |
| 3.1 |
|
|
| 2.1 |
|
| 2.1 |
HEAD PRESSURE | 70/21 |
| 275 | 19.3 |
| 293 | 20.6 |
| 316 | 22.2 | |||
|
|
|
| 80/27 |
| 289 | 20.3 |
| 318 | 22.3 |
| 338 | 23.8 |
|
|
|
| 90/32 |
| 293 | 20.6 |
| 338 | 23.8 |
| 360 | 25.3 |
PSIG | kg/cm2G | 100/38 |
| 297 | 20.9 |
| 343 | 24.1 |
| 380 | 26.7 | ||
SUCTION PRESSURE | 70/21 |
| 57 | 4.0 |
| 58 | 4.1 |
| 61 | 4.3 | |||
|
|
|
| 80/27 |
| 58 | 4.1 |
| 59 | 4.2 |
| 64 | 4.5 |
|
|
|
| 90/32 |
| 58 | 4.1 |
| 60 | 4.2 |
| 64 | 4.5 |
PSIG | kg/cm2G | 100/38 |
| 59 | 4.2 |
| 61 | 4.3 |
| 68 | 4.8 | ||
TOTAL HEAT OF REJECTION FROM CONDENSER |
| 19,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
Note:
1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
32