Hoshizaki KM-1301SAH-E, KM-1301SRH-E, KM-1301SWH-E 1270, 1142, 1950, 2070, 544, 228, 210, 260

Page 34

3. KM-1301SRH-E (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

 

 

 

 

 

 

 

 

 

70/21

1270

576

 

1233

559

 

1160

526

 

 

 

 

80/27

1241

563

 

1183

537

 

1100

499

lbs./day

 

kg./day

90/32

1233

559

 

1142

518

 

1062

482

 

100/38

1211

549

 

1123

509

 

988

448

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1950

 

 

1985

 

 

2028

CONSUMPTION

80/27

 

1977

 

 

2031

 

 

2071

 

 

 

 

 

 

 

 

 

 

 

 

 

90/32

 

1985

 

 

2070

 

 

2112

watts

 

 

 

100/38

 

1992

 

 

2080

 

 

2150

APPROXIMATE WATER

70/21

544

2.06

 

451

1.71

 

396

1.50

CONSUMPTION PER 24 HR.

80/27

473

1.79

 

330

1.25

 

314

1.19

 

 

 

 

 

 

 

 

m3/day

90/32

451

1.71

 

228

0.86

 

194

0.74

gal./day

 

100/38

342

1.30

 

220

0.83

 

163

0.62

FREEZING CYCLE TIME

70/21

 

33

 

 

34

 

 

36

 

 

 

 

80/27

 

34

 

 

36

 

 

38

 

 

 

 

90/32

 

34

 

 

37

 

 

40

min.

 

 

 

100/38

 

35

 

 

38

 

 

42

HARVEST CYCLE TIME

70/21

 

4.7

 

 

4.1

 

 

3.8

 

 

 

 

80/27

 

4.2

 

 

3.3

 

 

3.2

 

 

 

 

90/32

 

4.1

 

 

2.6

 

 

2.4

min.

 

 

 

100/38

 

3.4

 

 

2.6

 

 

2.3

HEAD PRESSURE

70/21

210

14.8

 

225

15.8

 

238

16.7

 

 

 

 

80/27

221

15.6

 

244

17.2

 

254

17.8

 

 

 

 

90/32

225

15.8

 

260

18.3

 

271

19.1

PSIG

kg/cm2G

100/38

225

15.8

 

263

18.5

 

282

19.8

SUCTION PRESSURE

70/21

50

3.5

 

51

3.6

 

55

3.8

 

 

 

 

80/27

51

3.6

 

52

3.7

 

57

4.0

 

 

 

 

90/32

51

3.6

 

53

3.7

 

58

4.1

PSIG

kg/cm2G

100/38

53

3.7

 

54

3.8

 

62

4.4

TOTAL HEAT OF REJECTION FROM CONDENSER

18,982

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,600

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

133

CU. IN (URC-14FE)

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

34

Image 34
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Indicates important information about the use and care Important Safety InformationSerious injury UnitSpecifications Icemaker KM-1301SAH-E air-cooledKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled Condenser Unit URC-14FESpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Minute Fill Cycle Sequence of OperationSequence Cycles and Shutdown Initial Harvest CyclePump-Out Cycle S4 Dip Switch Setting Pump-Out 1st Pump-Out FrequencyFreeze Cycle Harvest CycleMechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Cycle at Shutdown Mechanical Bin Control ActivationPump-Out Cycle Sequence Flow ChartCycle Steps Minute Fill Harvest Cycle Mechanical BC Bin Full Shutdown and RestartControl Board Control Board Layout Control BoardSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Time LEDs are OnDefault Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 Pump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3Time seconds Inlet Freeze Timer S4 dip switch 9 Harvest Pump Timer S4 dip switchFactory Use S4 dip switch S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch Control SwitchRefill Counter S5 dip switch 2 through Tank Water Tank Headmaster Service Drier Valve Thermistor KM-1301SAH-E air-cooled Wiring DiagramsAuxiliary Code T-0, U-0 U-0 Auxiliary CodeAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1780 13301240 13351950 12701142 2070IV. Service Diagnosis Diagnostic ProcedurePage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Shutdown Thermostatic Bin Control KM-1301SAH-E Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-EControl Board Check Thermostatic Bin Control Check KM-1301SAH-E Bin Control CheckMechanical Bin Control Check Single Unit Connection Detail Stacked Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Adjustment of Water Regulating Valve water-cooled model Thermistor CheckNo Ice Production Diagnostic ChartsNo Ice Production Possible Cause No Ice Production Possible Cause Freeze Up Freeze Up Possible Cause Harvest CycleFreeze Up Possible Cause Freeze Cycle Low Ice Production Possible Cause Long Harvest Cycle Low Ice ProductionLong Freeze Cycle Service for Refrigerant Lines Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Important Notes for Component Replacement ComponentVI. Cleaning and Maintenance Cleaning ProcedureIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Maintenance Remove the water from the icemaker water supply lineDrain the water tank