Hoshizaki KM-1301SWH-E II. General Information Construction, KM-1301SAH-E air-cooled

Page 11

II. General Information

A.Construction

1.KM-1301SAH-E (air-cooled)

 

Separators

 

 

Spray Tubes

 

Low-Side Service Valve

Inlet Water Valve

 

 

 

 

 

High-Side Service Valve

Evaporator Assembly

 

 

Expansion Valves

 

 

 

 

 

 

Water Supply Inlet

 

 

 

Junction Box

 

 

 

Hot Gas Valve

Cube Guides

 

 

Check Valves

 

 

 

High-Pressure

 

 

 

Switch

 

 

 

Air-Cooled

 

 

 

Condenser

Check Valve

 

 

Control Box

 

 

 

(water)

 

 

 

Water Pump

 

 

Fan Blade

 

 

 

Float Switch

 

 

Fan Motor

 

 

 

Compressor

 

 

Drier

 

 

 

 

Control Switch

Liquid Line Valve

 

 

Thermostatic Bin Control

Transformer Box

 

 

11

Image 11
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Unit Important Safety InformationSerious injury Indicates important information about the use and careKM-1301SAH-E air-cooled Specifications IcemakerKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled URC-14FE Condenser UnitSpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Initial Harvest Cycle Sequence of OperationSequence Cycles and Shutdown Minute Fill CycleHarvest Cycle S4 Dip Switch Setting Pump-Out 1st Pump-Out FrequencyFreeze Cycle Pump-Out CycleCycle at Shutdown Mechanical Bin Control Activation Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-EMechanical BC Bin Full Shutdown and Restart Sequence Flow ChartCycle Steps Minute Fill Harvest Cycle Pump-Out CycleControl Board Control Board Control Board LayoutTime LEDs are On LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Sequence StepHarvest Timer S4 dip switch 1 Controls and AdjustmentsDefault Dip Switch Settings Time seconds Inlet Pump-Out Timer S4 dip switch 3Pump-Out Frequency Control S4 dip switch 5 S4 Dip Switch Setting Pump Motor Time seconds Harvest Pump Timer S4 dip switchFactory Use S4 dip switch Freeze Timer S4 dip switch 9Refill Counter S5 dip switch 2 through Control SwitchFloat Switch Control S5 dip switch Tank Water Tank Headmaster Service Drier Valve Thermistor U-0 Auxiliary Code Wiring DiagramsAuxiliary Code T-0, U-0 KM-1301SAH-E air-cooledAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1335 13301240 17802070 12701142 1950Diagnostic Procedure IV. Service DiagnosisPage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Shutdown Thermostatic Bin Control KM-1301SAH-EControl Board Check Mechanical Bin Control Check Bin Control CheckThermostatic Bin Control Check KM-1301SAH-E Stacked Unit Connection Detail Single Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Adjustment of Water Regulating Valve water-cooled modelNo Ice Production Possible Cause Diagnostic ChartsNo Ice Production No Ice Production Possible Cause Freeze Up Possible Cause Harvest Cycle Freeze UpFreeze Up Possible Cause Freeze Cycle Long Freeze Cycle Low Ice ProductionLow Ice Production Possible Cause Long Harvest Cycle Refrigerant Recovery Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404A BrazingPage Component Important Notes for Component ReplacementCleaning Procedure VI. Cleaning and MaintenanceIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Remove the water from the icemaker water supply line MaintenanceDrain the water tank