Hoshizaki KM-1301SAH-E, KM-1301SRH-E, KM-1301SWH-E service manual Separators

Page 13

3. KM-1301SRH-E (remote air-cooled)

 

Separators

Spray Tubes

Low-Side Service Valve

 

Inlet Water Valve

High-Side Service Valve

Evaporator Assembly

High-Side Liquid Service Valve

Water Supply Inlet

 

 

Hot Gas Valve

 

Junction Boxes

Cube Guides

 

 

Check Valves

 

High-Pressure

 

Switch

 

Expansion Valves

Check Valve

Receiver Tank

(water)

 

Water Pump

 

Float Switch

Control Box

Compressor

Access Valve

 

Control Switch

Drier

 

Liquid Line Valve

 

Transformer Box

Mechanical Bin Control

 

13

Image 13
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Serious injury Important Safety InformationIndicates important information about the use and care UnitKM-1301SAH-E air-cooled Specifications IcemakerKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled URC-14FE Condenser UnitSpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Sequence Cycles and Shutdown Sequence of OperationMinute Fill Cycle Initial Harvest CycleFreeze Cycle S4 Dip Switch Setting Pump-Out 1st Pump-Out FrequencyPump-Out Cycle Harvest CycleCycle at Shutdown Mechanical Bin Control Activation Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-ECycle Steps Minute Fill Harvest Cycle Sequence Flow ChartPump-Out Cycle Mechanical BC Bin Full Shutdown and RestartControl Board Control Board Control Board LayoutNo. of Beeps Type of Alarm Every 3 sec LED Lights and Audible Alarm SafetiesSequence Step Time LEDs are OnDefault Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 Pump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3Time seconds Inlet Factory Use S4 dip switch Harvest Pump Timer S4 dip switchFreeze Timer S4 dip switch 9 S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch Control SwitchRefill Counter S5 dip switch 2 through Tank Water Tank Headmaster Service Drier Valve Thermistor Auxiliary Code T-0, U-0 Wiring DiagramsKM-1301SAH-E air-cooled U-0 Auxiliary CodeAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1240 13301780 13351142 12701950 2070Diagnostic Procedure IV. Service DiagnosisPage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Shutdown Thermostatic Bin Control KM-1301SAH-EControl Board Check Thermostatic Bin Control Check KM-1301SAH-E Bin Control CheckMechanical Bin Control Check Stacked Unit Connection Detail Single Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Adjustment of Water Regulating Valve water-cooled modelNo Ice Production Diagnostic ChartsNo Ice Production Possible Cause No Ice Production Possible Cause Freeze Up Possible Cause Harvest Cycle Freeze UpFreeze Up Possible Cause Freeze Cycle Low Ice Production Possible Cause Long Harvest Cycle Low Ice ProductionLong Freeze Cycle Service for Refrigerant Lines Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404A BrazingPage Component Important Notes for Component ReplacementCleaning Procedure VI. Cleaning and MaintenanceIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Remove the water from the icemaker water supply line MaintenanceDrain the water tank