D. Float Switch Check and Cleaning

The float switch is used to determine that there is sufficient water in the tank after the

1minute fill cycle and after each harvest cycle. The float switch is also used to determine that the appropriate volume of water has been converted into ice before switching out of the freeze cycle. No adjustment is required.

1. Float Switch Check

To check the float switch, follow the steps below.

1)Turn off the power supply.

2)Remove the front panel, then move the

 

control switch to the "OFF" position.

 

 

 

3)

Remove the insulation panel, then remove

 

 

 

 

the drain plug located on the lower front

 

 

 

 

part of the ice chute. See Fig. 3. Allow the

 

 

 

 

water tank to drain.

 

 

 

4)

Replace the drain plug in its correct

 

 

 

 

position. Be careful not to cross thread it.

 

 

 

5)

Remove the control box cover.

 

 

 

6)

Disconnect the black float switch

 

 

 

 

connector from the control board BLACK

Ice Chute

Float Switch Assembly

Drain Plug

 

K5 connector.

 

Fig. 3

 

7)Check for continuity across the float switch leads. With the water tank empty, the float switch should be open. If open, continue to step 8. If closed, follow the steps in "IV.D.2. Float Switch Cleaning." After cleaning the float switch, check it again. Replace if necessary.

8)Reconnect the black float switch connector to the control board BLACK K5 connector, then replace the control box cover in its correct position.

9)Move the control switch to the "ICE" position. Replace the insulation panel and the front panel in their correct positions, then turn on the power supply. After 1 minute, the 1-minute fill cycle should end and the initial harvest cycle should begin. If the initial harvest cycle begins, the float switch is good and the check is complete. If the initial harvest cycle does not begin, continue to step 10.

10)Turn off the power supply.

11)Remove the front panel, then move the control switch to the "OFF" position.

12)Remove the control box cover.

13)Disconnect the black float switch connector from the control board BLACK K5 connector.

14)Check for continuity across the float switch leads. With the water tank full, the float switch should be closed. If the float switch is closed and the icemaker will not switch from the 1-minute fill cycle to the initial harvest cycle, replace the control board.

If open, confirm that the water tank is full. If the tank is not full, check the water supply, water filters, and inlet water valve. If the tank is full, follow the steps in "IV.D.2. Float Switch Cleaning." After cleaning the float switch, check it again. Replace if necessary.

43

Image 43
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Unit Important Safety InformationSerious injury Indicates important information about the use and careKM-1301SAH-E air-cooled Specifications IcemakerKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled URC-14FE Condenser UnitSpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Initial Harvest Cycle Sequence of OperationSequence Cycles and Shutdown Minute Fill CycleHarvest Cycle S4 Dip Switch Setting Pump-Out 1st Pump-Out FrequencyFreeze Cycle Pump-Out CycleCycle at Shutdown Mechanical Bin Control Activation Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-EMechanical BC Bin Full Shutdown and Restart Sequence Flow ChartCycle Steps Minute Fill Harvest Cycle Pump-Out CycleControl Board Control Board Control Board LayoutTime LEDs are On LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Sequence StepDefault Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 Pump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3Time seconds Inlet S4 Dip Switch Setting Pump Motor Time seconds Harvest Pump Timer S4 dip switchFactory Use S4 dip switch Freeze Timer S4 dip switch 9Float Switch Control S5 dip switch Control SwitchRefill Counter S5 dip switch 2 through Tank Water Tank Headmaster Service Drier Valve Thermistor U-0 Auxiliary Code Wiring DiagramsAuxiliary Code T-0, U-0 KM-1301SAH-E air-cooledAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1335 13301240 17802070 12701142 1950Diagnostic Procedure IV. Service DiagnosisPage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Shutdown Thermostatic Bin Control KM-1301SAH-EControl Board Check Thermostatic Bin Control Check KM-1301SAH-E Bin Control CheckMechanical Bin Control Check Stacked Unit Connection Detail Single Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Adjustment of Water Regulating Valve water-cooled modelNo Ice Production Diagnostic ChartsNo Ice Production Possible Cause No Ice Production Possible Cause Freeze Up Possible Cause Harvest Cycle Freeze UpFreeze Up Possible Cause Freeze Cycle Low Ice Production Possible Cause Long Harvest Cycle Low Ice ProductionLong Freeze Cycle Service for Refrigerant Lines Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404A BrazingPage Component Important Notes for Component ReplacementCleaning Procedure VI. Cleaning and MaintenanceIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Remove the water from the icemaker water supply line MaintenanceDrain the water tank