e) Harvest Pump Timer (S4 dip switch 7)
CAUTION
Factory set for proper operation. Do not adjust. Adjustment outside of the factory default setting may result in damage to the icemaker.
Depending on the harvest pump timer setting, the pump motor energizes and runs the last 0 or 50 seconds of harvest. When the pump is on, water circulates over the evaporator. The water valve is open during harvest for a maximum of 6 minutes or the length of harvest minus 0 or 50 seconds (determined by the harvest pump timer setting), whichever is shorter.
When S4 dip switch 7 is on, the pump motor is energized through the #5 pin (DBu wire) on the control board K1 ten‑pin connector and the X1 relay (auxiliary code
S4 Dip Switch Setting | Pump Motor |
No. 7 | Time (seconds) |
|
|
ON | 50 |
|
|
OFF | 0 |
|
|
f) Factory Use (S4 dip switch 8)
Factory set for proper operation. Do not adjust. This must be left in the factory default position.
g) Freeze Timer (S4 dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible
S4 Dip Switch Setting | Time | ||
|
| (minutes) | |
No. 9 | No. 10 | ||
| |||
|
|
| |
OFF | OFF | 60 | |
|
|
| |
OFF | ON | 50 | |
|
|
| |
ON | OFF | 70 | |
|
|
| |
ON | ON | 60 | |
|
|
|
23