Hoshizaki KM-1301SWH-E LED Lights and Audible Alarm Safeties, Sequence Step, Time LEDs are On

Page 20

a)LED Lights and Audible Alarm Safeties

At startup, a 5-second delay occurs while the control board conducts an internal timer check. A beep occurs when the control switch is moved to the "ICE" position.

The red LED indicates proper control voltage and remains on unless a control voltage problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2. For details, see "II.B. Sequence of Operation."

 

Sequence Step

 

LED

 

Energized

 

 

 

Time LEDs are On

 

 

 

Components

 

 

Min.

 

Max.

 

Avg.

 

 

 

 

 

 

 

 

 

 

 

1-Minute Fill Cycle

4

 

WV

 

 

 

 

 

1 minute

Harvest Cycle

1, 4, 2

 

Comp, FMR, WV,

 

2 minutes

20 minutes

3 to 5 minutes

 

 

 

 

 

 

HGV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harvest Pump Timer

1, 3, 2

 

Comp, FMR, PM,

 

0 seconds

50 seconds

harvest pump timer

 

 

 

 

 

 

HGV

 

 

 

 

 

setting

Freeze Cycle

1

 

Comp, FM/FMR,

 

5 minutes

freeze timer

30 to 35 minutes

 

 

 

 

 

 

PM, LLV

 

 

 

setting

 

 

Pump-Out Cycle

1, 4*, 3, 2

Comp, FMR, WV*,

 

10 seconds

20 seconds

*pump-out timer

 

 

 

 

 

 

PM, HGV

 

 

 

 

 

setting

The built-in safeties shut down the unit and have alarms as listed below.

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

 

 

 

1

High Evaporator Temp.

Check for harvest problem (stuck HGV or relay), hot

 

(temperature > 127°F (53°C))

water entering unit, stuck HM, or shorted thermistor.

2

Harvest Backup Timer

Check for open thermistor, HGV not opening, TXV or

 

(harvest > 20 min. for two cycles

LLV leaking by, low charge, inefficient Comp., or WRV

 

in a row)

leaking by.

3

Freeze Timer

Check for F/S stuck closed (up), WV leaking by, HGV

 

(freeze > freeze timer setting for

leaking by, PM not pumping, TXV not feeding properly,

 

two cycles in a row)

LLV not opening, low charge, HM not bypassing, or

 

Timer is factory set using S4 dip

inefficient Comp.

 

switch 9 & 10

 

To reset the above safeties, press the "ALARM RESET" button with the power supply on.

 

 

 

6

Low Voltage

Red LED turns off if voltage protection operates.

 

(92Vac±5% or less)

The control voltage safeties automatically reset when

7

High Voltage

voltage is corrected.

 

(147Vac±5% or more)

 

Legend: Comp–compressor; FM–fan motor; FMR–fan motor-remote; F/S–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet water valve

20

Image 20
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker KM-1301SAH-E air-cooledKM-1301SWH-E water-cooled KM-1301SRH-E remote air-cooled Condenser Unit URC-14FESpecifications II. General Information Construction KM-1301SWH-E water-cooled Separators Sequence of Operation Sequence Cycles and ShutdownMinute Fill Cycle Initial Harvest CycleS4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Freeze CyclePump-Out Cycle Harvest CycleMechanical Bin Control KM-1301SWH-E, KM-1301SRH-E Cycle at Shutdown Mechanical Bin Control ActivationSequence Flow Chart Cycle Steps Minute Fill Harvest CyclePump-Out Cycle Mechanical BC Bin Full Shutdown and RestartControl Board Control Board Layout Control BoardLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Time LEDs are OnHarvest Timer S4 dip switch 1 Controls and AdjustmentsDefault Dip Switch Settings Time seconds Inlet Pump-Out Timer S4 dip switch 3Pump-Out Frequency Control S4 dip switch 5 Harvest Pump Timer S4 dip switch Factory Use S4 dip switchFreeze Timer S4 dip switch 9 S4 Dip Switch Setting Pump Motor Time secondsRefill Counter S5 dip switch 2 through Control SwitchFloat Switch Control S5 dip switch Tank Water Tank Headmaster Service Drier Valve Thermistor Wiring Diagrams Auxiliary Code T-0, U-0KM-1301SAH-E air-cooled U-0 Auxiliary CodeAuxiliary Code U-1 and Later PressureSwitch KM-1301SRH-E remote air-cooled Performance Data 1330 12401780 13351270 11421950 2070IV. Service Diagnosis Diagnostic ProcedurePage S4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Shutdown Thermostatic Bin Control KM-1301SAH-E Mechanical Bin Control KM-1301SWH-E, KM-1301SRH-EControl Board Check Mechanical Bin Control Check Bin Control CheckThermostatic Bin Control Check KM-1301SAH-E Single Unit Connection Detail Stacked Unit Connection DetailMechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Adjustment of Water Regulating Valve water-cooled model Thermistor CheckNo Ice Production Possible Cause Diagnostic ChartsNo Ice Production No Ice Production Possible Cause Freeze Up Freeze Up Possible Cause Harvest CycleFreeze Up Possible Cause Freeze Cycle Long Freeze Cycle Low Ice ProductionLow Ice Production Possible Cause Long Harvest Cycle Refrigerant Recovery Replacement of ComponentsService for Refrigerant Lines Brazing Evacuation and Recharge R-404APage Important Notes for Component Replacement ComponentVI. Cleaning and Maintenance Cleaning ProcedureIce Chute Float Switch Assembly Drain Plug Sanitizing Procedure Following Cleaning Procedure Maintenance Remove the water from the icemaker water supply lineDrain the water tank