TROUBLESHOOTING SECTION
WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni- cian. Many of the tests require that the unit have power to it and live electrical components be exposed.
USE EXTREME CAUTION WHEN TESTING THE MACHINE.
Symptom | Possible Cause | Action |
|
|
|
|
|
Low rinse temperature/low wash | Low inlet water temperature. | Ensure incoming water is 110 F at incoming |
|
temperature. |
| point of machine, may need to increase the |
|
|
| set point of the supply water heater. |
|
|
|
|
|
| Low gas pressure. | Check gas supply pressure. |
|
|
|
|
|
|
| Ensure proper operation of combination gas |
|
|
| cutoff valve. |
|
|
|
|
|
|
| Ensure manual gas cutoff valve is open. |
|
|
|
|
|
|
| Check for kinks in flexible gas supply line. |
|
|
|
|
|
| Improper circulation through system. | Check recirculating pump operation. Check |
|
|
| for obstructions. |
|
|
|
|
|
| Ensure set point is approximately 4.25 VDC. |
| |
|
|
|
|
| Defective | Check Ohms reading is between 950 and |
|
| may be flashing). | 1150 Ohms when probe is at room |
|
|
| temperature. Check for frayed wiring. |
|
|
| Ensure connection to control board. |
|
|
|
|
|
| Defective control board (ECB). | Perform |
|
|
| supplied to board is +12 VDC. Ensure green |
|
|
| LED light is flashing. |
|
|
|
|
|
High rinse temperature. | Ensure set point is approximately 4.25 VDC. |
| |
|
|
|
|
| ECO failure. (Overprotection feature is | Remove wire from ECO terminal. If burner |
|
| faulty and does not open at 210 F). | unit turns off, ECO may be defective. |
|
|
| Replace ECO. |
|
|
|
|
|