Symptom

Possible Cause

Action

 

 

 

Dishmachine will not run. No power to the

Service breaker tripped.

Reset breaker. If breaker trips again,

unit.

 

immediately contact an electrician.

 

 

 

 

Incoming power lines not installed in control

Install power lines.

 

box.

 

 

 

 

 

Incoming power lines connections not

Tighten connections.

 

tightened.

 

 

 

 

Dishmachine will not run. There is power to

Door switch shorted out or is disconnected.

Check to ensure door switch wires are

the unit.

 

connected correctly. If so, replace door

 

 

switch.

 

 

 

 

Misadjusted or faulty "cycle reset" cam

Replace microswitch.

 

microswitch.

 

 

 

 

Machine runs, but there is not water.

No water supply to machine.

Check to ensure that all water valves are

 

 

open and that water is being supplied to the

 

 

machine at 20 PSI.

 

 

 

 

Incoming water supply solenoid not

Check to ensure that valve is wired

 

operating.

correctly. If so, replace valve.

Dishmachine fills continuously, even when the machine is off.

Incoming water supply solenoid not operating.

Check to ensure that valve is wired correctly. If so, replace valve.

Dishmachine fills continuously, only when the power is on.

Incoming water supply solenoid not operating.

Check to ensure that valve is wired correctly. If so, replace valve.

12

Image 14
Contents Technical Manual Table of Contents Specifications of the Tempstar GP Installation Instructions GAS Connection Operation Instructions Overview of Operation Overview of Operation Thermostat Adjustment Procedure AUTO-CALIBRATION Procedure Auto CalibrationTesting and Setting the Set Point Temperature Electronics Control Board ECBTesting the Thermistors To test the temperature at the T-in ThermistorControl Board LED Light Indications Green LED is offTroubleshooting Section Symptom Possible Cause ActionTroubleshooting Section Leaks do not USE Flame Low rinse temperature/low wash Low inlet water temperature Polarity will Damage the Circuit Boards DSICombination cutoff valve and the modulating Check ignition wire. Check that lights above Dimensions Table Dimensions Main Assembly Shown Not ShownControl BOX Assembly Front View QTY Description MFG noControl BOX Assembly TOP View Control BOX ASSEMBLY-TOP View Hood Assembly Cantilever ARM Assembly TUB Assembly Back of TUB, & Drain Assembly Lower Assembly Right Side Incoming Plumbing Assembly Incoming Plumbing Parts Lists GAS Pack Assembly Upper WASH, & Rinse ARM Assembly Lower WASH, & Rinse ARM Assembly Steam Coil Assembly Steam Coil Assembly Parts Lists Rinse Tank Assembly Electronic Control Drawer Components RED Green LEDElectrical Diagram 208/240 Volt 60 Hertz 1 Phase