| TROUBLESHOOTING & REPAIR |
| |||||||||
| Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |||||||||
| detailed in the beginning of this manual. |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
|
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |||||||
|
| (SYMPTOMS) |
|
| MISADJUSTMENT(S) |
|
| COURSE OF ACTION |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
|
|
| The voltmeter reads “00” in Stick |
|
| 1. Inspect to assure that the arc |
|
| 1. | Check for loose connectors at |
| |||
|
| Mode, and there is no output from |
|
| start switch is in the on |
|
|
| the SCR bridge and at the |
|
| ||
|
| the machine when in the TIG |
|
| (closed) position when |
|
|
| Protection/Snubber board. (J10) |
| |||
|
|
|
| welding in the TIG Mode. |
|
|
| and (J11). See Figure F.2 at |
|
| |||
|
|
|
|
|
|
|
|
|
| end of this Guide for location. |
| ||
|
|
|
|
|
|
|
|
| 2. | Check the wiring to the Control |
| ||
|
|
|
|
|
|
|
|
|
| Transformer (T2). Observe |
|
| |
|
|
|
|
|
|
|
|
|
| directions on decal. |
|
| |
|
|
|
|
|
|
|
|
| 3. | The Protection/Snubber board |
| ||
|
|
|
|
|
|
|
|
|
| may be faulty. See |
|
| |
|
|
|
|
|
|
|
|
|
| Protection/Snubber Board |
|
| |
|
|
|
|
|
|
|
|
|
| Continuity Test. |
|
| |
|
|
|
|
|
|
|
|
| 4. | Check the Control Transformer |
| ||
|
|
|
|
|
|
|
|
|
| (T2). See Control Transformer |
| ||
|
|
|
|
|
|
|
|
|
| Voltage Test. |
|
| |
|
|
|
|
|
|
|
|
| 5. | Check the polarity switch (S2) |
| ||
|
|
|
|
|
|
|
|
|
| for loose or broken connections. |
| ||
|
|
|
|
|
|
|
|
| 6. | Check the SCR bridge. See |
|
| |
|
|
|
|
|
|
|
|
|
| Static and Active SCR Tests. |
|
| |
|
|
|
|
|
|
|
|
| 7. | If all previous tests are OK - |
|
| |
|
|
|
|
|
|
|
|
|
| then replace the Control board. |
| ||
|
|
|
|
|
|
|
|
|
|
| |||
|
| Machine does not respond (no gas |
|
| 1. Machine MUST be in one of |
|
| 1. | Check trigger circuit. See Arc |
| |||
|
| flow, no high frequency and no |
|
| the TIG Modes. |
|
|
| Start Trigger Circuit Test |
|
| ||
|
| open circuit voltage) when arc |
|
|
|
|
| 2. | Check the Control transformer |
| |||
|
| switch or amptrol is activated - |
|
| 2. The arc start switch or amptrol |
|
|
| |||||
|
| displays and fan working. Note: |
|
| may be defective. Check for |
|
|
| (T2). See Control Transformer |
| |||
|
| Machine may have OCV in the |
|
| continuity between pins “D” |
|
|
| Voltage Test. |
|
| ||
|
| Stick Mode. |
|
| and “E” on cable connector |
|
| 3. | Protection/Snubber board may |
| |||
|
|
|
|
|
| when arc switch or amptrol is |
|
|
| ||||
|
|
|
|
|
| activated. |
|
|
| be faulty. See |
|
| |
|
|
|
|
|
|
|
|
|
| Protection/Snubber Board |
|
| |
|
|
|
|
|
|
|
|
|
| Continuity Test. |
|
| |
|
|
|
|
|
|
|
|
| 4. | If all previous tests are OK - |
|
| |
|
|
|
|
|
|
|
|
|
| then replace the Control board. |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call