TROUBLESHOOTING & REPAIR |
|
TYPICAL SCR GATE VOLTAGE WAVEFORM
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
•Perform all voltage and waveform checks with high frequency circuit OFF.
_____________________________________________________________________
CH1
0 volts
2 volts | 5ms |
Return to
Return to Section TOC
Return to
Return to Master TOC
This is the typical SCR gate pulse voltage waveform. The machine was in an open circuit condition (no load) and operating properly. Note that each vertical division represents 2 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at SCR
gate and cathode: (+) probe to gate,
SCOPE SETTINGS
Volts/Div | 2 V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|