| TROUBLESHOOTING & REPAIR |
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
AC TIG MODE
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
•Perform all voltage and waveform checks with high frequency circuit OFF.
_____________________________________________________________________
CH1
0 volts
50 volts | 2ms |
Return to
Return to Section TOC
Return to
Return to Master TOC
This is the typical AC output voltage wave- form generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 2 milliseconds in time.
Note: Scope probes connected at machine
output studs: (+) probe to electrode,
SCOPE SETTINGS
Volts/Div | 50 V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |