INSTALLATION
Boring the wall
If you want to use the hood in suction version with the air outlet at the back of the hood, make sure to follow the indications given below in the drawing for a correct boring operation of the air outlet opening.
Tipo Cappa | 45 | 60 |
X | 180 | 240 |
|
|
|
X | X |
300 |
|
11a | 250 |
| |
| 808 |
540 |
|
650 mm min |
|
Rear air outlet
zone
On the wall, trace:
•a vertical line up to the ceiling or top limit, at the centre of the area where you intend to fit the hood;
•a horizontal line at: 650 mm min. above the cooking hob;
•As shown, mark a reference point at 808 mm above the horizontal reference line, and at X mm (X= see table in figure) to the right of the vertical reference line.
•Repeat this operation on the opposite side, checking levelling.
•Drill the points marked using a ø 12 mm bit
•Insert plugs with screws and brackets 11a in the holes then tighten them.
EN |
| 1 |
| 17 |