Franke Consumer Products FPL 606 Hood body assembly, Connections, AIR Outlet in Suction Version

Page 18

Hood body assembly

Adjust the two screws Vr of brackets 11a, by just placing them in position.

Hook the hood body to the two brackets 11a.

Pull the Comfort Panel to open it, remove the filters one by one, push them towards the rear part of the unit and pull downwards at the same time .

From inside the hood body, tighten the screws Vr to level the body.

11a

Vr

Connections

AIR OUTLET IN SUCTION VERSION

To fit the hood in suction version, connect the hood to the outlet by means of a 150 o 120 mm ø rigid or flexible pipe, the choice of which is left to the technician. The pipe can be fitted either at the top or at the back of the hood.

Before proceeding with the connections, and in case they have not been removed yet, remove the inclinable grid 8 and pvc pipe

7.The reduction flange 9 should only be removed to carry out

150ø connections.

REAR OUTLET

Please bear in mind that the exhaust opening must be carried out following the drawing indicated in the wall boring para- graph.

Break the rear outlet using pliers.

When using a 120 mm ø pipe, insert the reduction flange 9 in the hood body outlet.

Keep the pipe in position using clamps. The necessary material is not supplied.

Remove any charcoal anti-odour filters, if used.

TOP OUTLET

Remove the inclinable grid 8.

When using a 150 mm ø pipe, break the top air outlet along the pre-cut line with pliers.

When using a 120 mm ø pipe, insert the reduction flange 9 in the hood body outlet.

Keep the pipe in position using clamps. The necessary material is not supplied.

Remove any charcoal anti-odour filters, if used.

 

9

ø 150

ø 120

 

EN

 

1

 

18

Image 18
Contents Istruzioni per l’uso e l’installazione Indice Index Sommaire Inhaltsverzeichnis Içerikler USO InstallazioneConsigli E Suggerimenti ManutenzioneCaratteristiche Ingombro ComponentiInstallazione Foratura PareteMontaggio Corpo Cappa ConnessioniUscita Aria Versione Aspirante Uscita Aria Versione Filtrante Connessione ElettricaUSO Quadro ComandiManutenzione Pulizia dei Confort PanelTelecomando Opzionale Illuminazione Filtri antigrassoFiltri antiodore al Carbone attivo Versione Filtrante SostituzioneRecommendations and Suggestions InstallationMaintenance USECharacteristics Dimensions ComponentsInstallation Boring the wallHood body assembly ConnectionsAIR Outlet in Suction Version AIR Outlet in Recirculating Version Electrical ConnectionUSE Control panelMaintenance Cleaning the Comfort PanelsRemote Control Optional Activated charcoal filter Recirculation version Light ReplacementGrease filters LightingConseils ET Suggestions UtilisationEntretien Caracteristiques Encombrement ComposantsPerçage de la Paroi Montage du Corps de la Hotte ConnexionsSortie D’ÉVACUATION DE L’AIR Version Filtrante Branchement ElectriqueTableau des commandes UtilisationTelecommande Fournie SUR Demande EntretienNettoyage des Confort Panel Filtres anti-graisse Remplacement Filtre AU Charbon ActifRemplacement Lampes Filtre anti-odeur Version filtranteBedienung Empfehlungen UND HinweiseMontage WartungCharakteristiken Platzbedarf KomponentenMontage Bohren der WandMontage des Haubenkörpers AnschlüsseLuftaustritt BEI Absaugversion Luftaustritt BEI Umluftversion ElektroanschlussBedienung BedienfeldWartung Reinigung der Confort PanelFernbedienung Option Beleuchtung FettfilterGeruchsfilter Umluftversion Austauschen DER Aktivkohle FilterTavsiyeler VE Öneriler MontajÖzellikler BoyutlarMontaj Duvarın delinmesiDavlumbaz gövdesinin montajı BağlantılarEmme Versİyonu Hava Çikişi Elektrİk Bağlantisi Kullanim Kumanda TablosuBakim Telekumanda OpsİyonelDeğİştİrİlmesİ Yağ tutucu filtrelerAktif karbonlu koku giderici filtreler Filtreli Model Ampullerİn DeğİştİrİlmesİPage 436002992ver1